3-5

S101
Switch No.
Function Up (Off) Down (On)
1 Unit Address (Binary Code) [0] 1
2 [0] 1
3 [0] 1
4 [0] 1
5 [0] 1
6 Normal/Download
(Baud rate set by switches 7 & 8)
[Normal] Download
7 Baud Rate for Remote [up] down
8 Control or Download Operation
(Mode set by switch 6) [up] down
3.5.1 Switch nos. 1-5 - Unit Address

A unique address can be assigned to each DP503 in a multi-unit installation for

remote control applications using the RS-232 connector J108 Rem/Download.

Individual units can be uniquely controlled using this feature.

Note While individual units can be controlled this way, status information from a particular unit cannot be
retrieved remotely using the serial port. Instead, individual status information can be retrieved using the
separate connector J109 Status.

The address is set using conventional binary codes as follows:

S101- S101-
Unit
Address
12345 Unit
Address
1234 5
000000 16 100 0 0
100001 17 100 0 1
200010 18 100 1 0
300011 19 100 1 1
400100 20 101 0 0
500101 21 101 0 1
600110 22 101 1 0
700111 23 101 1 1
801000 24 110 0 0
901001 25 110 0 1
10 01010 26 110 1 0
11 01011 27 110 1 1
12 01100 28 111 0 0
12 01101 29 111 0 1
14 01110 30 111 1 0
15 01111 31 111 1 1