Dometic 3200 Series owner manual Toilet Operation, Remove Red Cap From Middle

Models: 3200 Series

1 12
Download 12 pages 10.44 Kb
Page 6
Image 6
STEP 18: REMOVE RED CAP FROM MIDDLE
2. To flush toilet, press flush handle down. Release handle to let flush ball snap back into position.
FLUSHING OPERATION

STEP 17: Connect the positive (+) 12 VDC lead to the red wire and the negative (-) lead to the black wire (fig. 18).

Fig. 18

STEP 18: REMOVE RED CAP FROM MIDDLE

OF FLANGE ADAPTER BEFORE FINAL TOILET INSTALLATION.

IMPORTANT – DO NOT ATTEMPT TO SLIDE THE TOILET OVER THE FLANGE ADAPTER. THE TOILET MUST BE SET DOWN OVER THE ADAPTER TO PREVENT POSSIBLE DAMAGE.

STEP 19: Set the toilet in place (fig. 19) and secure to floor with the #14x2-1/2 inch long lag bolts (fig. 20). Install decora- tive bolt caps by pushing them onto bolt heads (fig. 21).

STEP 20: Place the rear access cover on the back of the toilet. Press down firmly to seat the fastening strips.

Fig. 19

 

Fig. 20

 

 

 

Fig. 21

STEP 21: Turn on electrical power and water to toilet. Lift flush handle and fill toilet bowl with water. Wait one hour, then inspect the floor around and under the rear of the toilet for leaks or dampness.

Toilet Operation

1.Fill freshwater tank and add deodorant to holding tank through toilet bowl.

2.Make sure all guests understand the operation of the toilet system and the flushing instruction label is easy for guests to read. This label is located under the seat, and is easily read when the seat is raised.

3.Shut off the toilet system before servicing and do not leave the vehicle with toilet system breaker on.

4.Never use drain openers, alcohol, solvents, etc. in the toilet.

5.If the toilet does not function properly, refer to the Troubleshooting section of this manual and repair as neces- sary. If problem persists, contact your local SeaLand product dealer or see the Customer Service section of this manual.

1.To add water to the toilet before using (if necessary), raise flush handle until desired water level is reached.

3.Do not dispose of sanitary napkins or other non-dissolv- ing items in toilet, such as facial tissue or paper towels. These items can plug the system.