Freightliner Refrigerator Troubleshooting Guide

750000005 (TJ18F)

750000011 (TJ22F)

750000026 (TJ18FP3)

The LOAD DUMP module is defective if the unit operates while wired to the DANFOSS module. Replace Load Dump module.

9.If LOAD DUMP module is working properly, check the speed resistor. This component is used to control the speed of the compressor and is located on the “T” terminal of the DANFOSS module.

Speed Resistor

Turn off power and disconnect the speed resistor from the Danfoss module. Remove the speed resistor from the blue wire and connect the blue wire on the Danfoss module terminal “T” where the speed resistor was removed.

Connect power (12volts) back to the unit. If the unit performs, the speed resistor is faulty. Replace Speed Resistor.

10.Test the Thermostat Circuit. Remove the blue wire that is connected on terminal

“C” and remove the (black) Speed resistor (attached to the other blue wire) connected to terminal “T” of the Danfoss module. These two wires represent the thermostat circuit.

Blue Wire from thermostat

Speed Resistor connected to other blue wire from thermostat

Make sure the thermostat knob is turned on, remove the speed resistor, set multimeter to check continuity and connect meter leads to these wires as shown.

DOMETIC CORPORATION, ENVIRONMENTAL DIVISION

 

P.O. Box 15299 I Richmond, VA 23227 USA

 

Phone +804 746 1313 Fax +804 746 7248

 

www.dometic.com

Page 5 of 20

Page 5
Image 5
Dometic 750000005 (TJ18F), 750000026(TJ18FP3), 750000011(TJ22F) warranty Speed Resistor