Freightliner Refrigerator Troubleshooting Guide

750000005 (TJ18F)

750000011 (TJ22F)

750000026 (TJ18FP3)

Specific Trouble-Shooting of

Electrical Components

A:Check incoming voltage

1.Hold multimeter leads to the positive (+) and negative (-) terminals of the load dump module. The red lead from the multimeter is held to the “+” terminal and black lead from the multimeter is held to the “-“ terminal. You should read positive voltage. If the reading is negative, check DC polarity. If it is reversed, correct wire connections.

2.The inrush current must not drop the voltage more than 3% or .36 volts when the compressor is initially energized. Monitor this voltage by using a multimeter at start-up. For 12vdc system, the cutout is around 10.4 volts and the cut-in is 11.7 volts. If there is a drop in current, at start-up, below the cut out voltage, then the compressor will not operate. A drop in voltage will occur if the wire size is too small or poor connection.

3.Verify that voltage at unit is equal to voltage at source. If the voltage is less than at the source then the wire used from source to unit is too small.

B. Checking the Compressor

1.Remove all wires from compressor module (make note where they are connected).

2.Removed Danfoss module from the compressor by removing the mounting screw and twisting the module to the rear to disconnect it from the compressor. See

Section A #12 in “General Troubleshooting” Section.

3.Compressor windings can be checked for defects by measuring the resistance on the current lead-in pins. If the measured values between all pins are approximately the same (approximately 2.2-2.5 ohms). The compressor motor is OK.