Dometic 9093100-(X)PR, 9093200-(X)PR manual F. Changing Motor Filter

Models: 9093200-(X)PR 9093100-(X)PR

1 8
Download 8 pages 55.52 Kb
Page 7
Image 7
F.CHANGING MOTOR FILTER

CENTRAL RV VACUUM

F.CHANGING MOTOR FILTER

1.Remove completely the door with the dust bag.

2.Remove the motor filter from the bottom of the vacuum cleaner cavity. See FIG. 6.

3.Install the new motor filter with dark side up. Tuck in the corners so that the filter lays flat on the grid in the cavity.

Note: Clean the dirty motor filter by washing in mild soap by hand. Do not machine wash. Let filter air dry before replacing. See note in Step D Changing Dust Bag.

FIG. 6

FRONT

 

PANEL

 

FILTER MUST

MOTOR FILTER

LAY FLAT ON

WITH DARK

GRILL TUCK

SIDE UP

CORNERS IN

G.CHANGING EXHAUST FILTER

1.The exhaust filter is located in the opening at the bottom of the vacuum cleaner front panel.

2.Push the plastic pins on the gate upward, then pull the gate frame forward and down. See. FIG. 7.

3.Turn the switch to “ON” to start the vacuum cleaner. The exhaust of the vacuum cleaner should blow the exhaust filter out the opening. Turn the vacuum cleaner “OFF”. See FIG. 4.

FIG. 7

FRONT

PANEL

EXHAUST

FILTER

GATE

7

H.TROUBLESHOOTING

1.If your motor stops check the following:

a.Vacuuming large amounts of dust other than household dirt, (drywall dust, fine wood dust, etc.) can block the pores of the dust bag rap- idly even if the dust bag is new.

b.The vacuum hose could be clogged.

c.The vacuum tool could be clogged.

d.The motor filter is dirty and should be cleaned or replaced.

e.The exhaust filter should be checked and cleaned or replaced.

CAUTION

All Dometic built-in vacuum systems are equipped with a thermal overload protector at the motor to prevent overheating. If the motor stops, indicating overheating, push the switch to the “OFF” position and check the above Troubleshooting 5 points. The motor will reset itself after about 1-1/2 hours. If the problem should reoccur more than 3 times, please call the factory or selling dealer.