Specification Details

INTERNAL UNIT - EVAPORATOR/HEATER/COMPRESSOR

Model

Cooling

Capacity (BTU/Hr)

Heating Capacity***

Control

Height (in) Width (in) Length (in)

Weight (lbs) Cool amps** Heat amps** Refrigerant

ECEQ7*

7,000

cooling

only

smart digital

11.75

10.25

19.25

53

7.3

n/a

R-417A

EHCEQ7*

ECEQ10

EHCEQ10

EHCEQ10

7,000

10,000

10,000

10,000

1 kW

cooling

7500 BTU

1.5 kW

 

only

Espar

 

 

 

Ready

 

smart

smart

smart

smart

digital

digital

digital

digital

11.75

11.63

11.63

11.63

10.25

11.12

11.12

11.12

19.25

20.19

20.19

20.19

53

60

60

62

7.3

11.8

11.8

11.8

8.2

n/a

1.0

13

n/a

R-417A

R-417A

R-417A

 

 

 

 

EHCEQ10

10,000

2 kW

smart digital

11.63

11.12

20.19

62

11.8

17

R-417A

ECEXQ14

EHCEQ14

14,000

14,000

cooling

1.5 kW

only

 

smart

smart

digital

digital

11.6911.69

13

13

2222

6465

14.514.5

n/a 13

R-417A R-417A

EHCEQ14

14,000

2.5 kW

smart digital

11.69

13

22

65

14.5

21

R-417A

EHCEQ14

14,000

2.5kW 2-stage

smart digital

11.69

13

22

65

14.5

11.4+ 10.4

R-417A

EHCEQ14

14,000

4kW

2-stage

smart digital

11.69

13

22

65

14.5

23.2+ 12.1

R-417A

EXTERNAL UNIT - CONDENSER

Model

Cooling

Capacity (BTU/Hr)

Height (in) Width (in) Length (in)

Weight (lbs) Cool amps** Heat amps** Refrigerant

ACCD7

7,000

6.125

11.3125

21.875

10

n/a

n/a

R-417A

ACCE10

10,000

6.125

12.5

24.5

12

n/a

n/a

R-417A

ACCE14

14,000

6.625

12.5

24.5

13

n/a

n/a

R-417A

Air Out

Electrical box can be remotely mounted

 

W

up to 2.5 ft. away from inside unit.

 

 

Box dimensions are 10.3”H x 9”W x 5”D.

 

 

Approximate weight is 16 lbs.

 

 

 

 

Refrigerant

H

Return Air

Connectors

Filter

 

 

 

L

Condensate Drain 3/8” NPT

NOTES: The system is rated to provide full capacity at 95˚F (35˚C) outside temperature. Actual performance will be affected by factors such as ambient temperature and humidity, insulation, direct sunlight and reflected heat. *Electrical box is separate for all models except for this model where the electrical box is integral. **Power consumption at 120VAC. ***Other heat capacities are optional. Espar Ready unit is set up to operate the Espar D2 Airtonic Heater. The heater draws approximately 2.8 amps @ 12VDC. 1 kW of electric heat equals 3,414 BTU/hr.

Recommended Duct & Min. Grill Sizes

W

Mounting Holes (Typ. 4)

 

1/4” (6mm) Dia.

L

 

Refrigerant

Connectors

H

BTU/Hr

Return Air (sq in/cm)

Discharge Air (sq in/cm)

Recommended Duct Size (in/mm)

7,000

10,000

80/520

100/650

50/325

60/390

5/127

5/127

 

 

14,000

144/936

80/520

7/178

Air In

DOMETIC • US Patent 7,140,192 • US Patent 7,171,822 US Patent 5899081 • Other Patents Pending

Dealer:

DOMETIC ENVIRONMENTAL CORPORATION

P.O. Box 15299 I Richmond, VA 23227 USA I 804-746-1313 I Fax 804-746-7248 www.dometictruck.com I sales@dometictruck.com

United States & Canada Service Only:

Weekdays 8:00 am to 5:00 pm (Eastern Time) 804-746-1313

All other times 888-440-4494

Environmentally

Responsible

ID: 2317 Rev. 20080319

Page 2