CERTIFIED INSTALLATION

Certified installations require one roof vent and one lower side vent.

For “Certified Vent System Kits” see page 19.

For further information contact your dealer or distributor.

METHODS OF INSTALLATION

The method of installation is shown in FIG. 9. It is essen- tial that all maximum or minimum dimensions are strictly maintained as the performance of the refrigerator is de- pendent on adequate flow of air over the rear of the re- frigerator.

NOTE: The upper vent should be centered over the condenser coil at the back of the refrigerator.

Ventilation height

Condenser

FIG. 9

LOWER VENT CUTOUT

13-5/8”

28-5/8”

VENTILATION HEIGHTS

Installation with roof

Minimum ventilation

vent and lower side vent

heights in:

 

 

 

 

Refrigerator

Inches

 

mm

NDA 1402

 

 

 

69-1/8

 

1756

 

 

 

 

CLEARANCES

Minimum clearances in inches to combustible materials are:

G:

Top

0

K:

Side

0

L:

Bottom

0

M:

Rear

0

N:See NOTE: Clearance “N” below.

NOTE: Clearance “M” is between the rearmost part of the refrigerator and the wall behind the refrigerator.

NOTE: Clearance “N” is the distance between the bot- tom of the lower vent to the roof material. For ventilation height, see table VENTILATION HEIGHTS

See Figures 9, and 10.

G

K

L

FIG. 10

N

K M

NOTE: Wood Strip MUST be in place

8

Page 7
Image 7