3. REPLACING A HALOGEN LAMP

3. REPLACING A HALOGEN LAMP

! CAUTION

Turn off the refrigerator before replacing the lamp. Wear gloves as protection against hot lamp, broken glass and as protection of the new lamp.

Refrigerator

The lamp is located at the top of the refrigerator com- partment.

To replace the lamp proceed as follows:

unhook the tab on the lamp cover by pressing in with the thumb on the side of the lamp cover.

remove the lamp cover.

with gloves, pull out the lamp from the socket and replace it with a new 12V, 10-watt(maximum) halogen lamp base G4.

replace the lamp cover by placing the two tabs into the corresponding slots of the lamp house and press the tab into place.

Freezer

The lamp is located on the right side of the freezer com- partment.

To replace the lamp proceed as follows:

unhook the tab on the lamp cover by pressing in with the thumb on the side of the lamp cover.

remove the lamp cover.

with gloves, pull out the lamp from the socket and replace it with a new 12V, 5-watt(maximum) halogen lamp base G4.

replace the lamp cover by placing the two tabs into the corresponding slots of the lamp house and press the tab into place.

TROUBLESHOOTING

The Refrigerator Does Not Cool Properly

A.Burner jet clogged.

Clean. (See section Maintenance & Service, Item 2. Periodic Maintenance, Paragraph D. Item 1-13.)

B.Check level of refrigerator.

C.Venting problem.

Restriction in air flow across cooling unit.

D.Flue baffle not inserted properly in flue tube.

E.Improperly set thermostat.

(See section Operating Instructions, part Start Up Instructions. “Set thermostat range”).

F.Burner dirty.

Clean. (See section Maintenance & Service, Item 2. Periodic Maintenance, Paragraph D. Item 1-13.)

G.LP gas pressure low at burner.

Set main regulator so pressure does not drop below 11 inches water column at pressure tap.

H.Burner not located properly under flue tube. Relocate.

I.Burner damaged. Replace.

J.Odors from fumes.

1.Dislocated burner.

2.Damaged burner.

3.Dirty flue tube.

K.FUSES

See wiring diagram

If the refrigerator fails to work, check the following points before calling a service technician:

that the fuses are intact

that the power cord is plugged in

that 12 volt DC is connected to the refrigerator

The refrigerator is equipped with an overheating protec- tion.

An authorized service technician can check if it has been triggered or not.

NOTE: AVOID SPRAYING WATER THROUGH THE REFRIGERATOR VENTS WHILE WASHING YOUR RV.