Dometic NDR1292-S dimensions Drain water hose, Fig. Fig, Two screws installed in the top frame

Models: NDR1292-S

1 16
Download 16 pages 23.24 Kb
Page 6
Image 6
FIG. 5

FIG. 5

FIG. 6

2.Secure the refrigerator and the lower front strip with two screws: One screw through each hinge. See FIG 6.

Step 2: Two screws installed in the top frame.

The top decoration panel must be removed from the re- frigerator before the screws can be installed.

Open the doors and remove the four screws that secure the top decoration panel to the top frame. Two screws are accessible from underneath see FIG. 7, the second two screws that secure the decoration panel to the front frame are located on each side of the lock retainer.

Carefully tilt the top decoration panel and lift up to re- move from top frame. Be careful not to damage the cir- cuit board and wires.

FIG. 7

1

Install the hvo screws in the top frame, the holes are accessible from underneath .

Seal the opening for the screws with aluminum tape. Replace the top decoration panel with its four screws. Be careful not to pinch the wires behind the panel.

STEP 3: Two scw.vs installed in the rear base.

See FIG. 8.

Failure to follow the sequence in securing refrigerator in enclosure can cause leakage between the frame and cabinet .

FIG. 6

A

Any space between the counter, storage area or ceiling

and topofthe refrigeratorgreaterden l-l/Z inchesshould be blocked. The heat produced at the rear of the refrig- erator will become trapped in this space, making the top of the refrigerator hot and reduce the efficiency of the refrigerator .

Drain water hose

A hole must be drilled through flooring see FIG. 8.

The hole must be drilled in the cut out opening of the base plate at the rear of the refrigerator. The installer MUST make sure that the hose does not kink when run through the floor. Seal around the hose that goes through the drilled hole. Ifa longer hose than supplied is required to get the water to drain outside of the vehicle, the in- staller will have to supply the extra length of hose.

TESTING LP GAS SAFETY

SHUTOFF

The gas safety shutoff must be tested after the re- frigerator is connected to LP gas supply.

To test the gas safety shutoff proceed as follows:

1 . Start the refrigerator according to the instructions, and switch to GAS mode. (See start up instruc- tions).

2.Check that the gas flame is lit and the GAS mode indicator lamp (C) is on.

3 . Close the manual gas shutoff valve at the back of the refrigerator. (See FIG. 1).

4.Wait for one minute. The CHECK indicator lamp

(D)should be on and the GAS mode indicator lamp

(C)should be off.

5.Remove protection cover (see FIG. 1) and open the manual gas shutoff valve. Do not change any button positions on the control panel. Apply a non- corrosive commercial bubble solution to the burner jet orifice.

6.No bubbles should appear at the opening of the burner jet orifice. The presence of bubbles indi- cates a defective gas safety shutoff and sewice is required.

7.If no bubbles were present at the burner jet orifice, it should be rinsed with fresh water. Be careful not

to damage the burner jet orifice. Replace cover and press the main power ON/OFF button (1) OFF and back ON. Normal operation of the burner should return. Allow the burner to operate for a minimum

of five minutes.

6

Page 6
Image 6
Dometic NDR1292-S Drain water hose, Fig. Fig, Two screws installed in the top frame, Two scw.vs installed in the rear base