CERTIFIED INSTALLATION
Certified installations require one roof vent and one lower side vent.
For “Certified Vent System KWsee page 14.
For further information contact your dealer or distribu- tor.
METHODS OF INSTALLATION
The method of installation is shown in FIG. 9. It is es- sential that all maximum or minimum dimensions are strictly maintained as the performance of the refrigera- tor is dependent on adequate flow of air over the rear of the refrigerator.
NOTE: The upper vent should be centered over the condenser coil at the back of the refrigerator.
FIG. 9
LOWER VENT CUTOUT
L
FIG. 10
VENTILATION HEIGHTS
CLEARANCES
Minimum clearances in inches to combustible materials are:
G: | TOP | 0 |
K: | Side | 0 |
L: | Bottom | 0 |
M: | Rear | 0 |
N : | See NOTE: Clearance “N” below . |
NOTE: Clearance “M” is between the rearmost part of the refrigerator and the wall behind the refrigerator.
NOTE: Clearance “N” is the distance between the bot- tom of the lower vent to the roof material. For ventilation height, see table VENTILATION HEIGHTS
See Figures 9, and 10.
NOTE: Wood Strip
MUST be in place