F.Replace door on lower hinge pin. Replace upper hinge pin and bushings removed in Step A.

G.Check that the door closes properly and seals all around.

A.Remove the door. See Section 12.

B.Remove the lower trim molding. (NOTE: Trim molding is not installed on new units in cartons)

C.Fit the new panel in place and slide it up as far as possible.

D.Fit the trim molding back in place.

13. INSTALLATION OF DECORATIVE DOOR PANEL

The door panel can easily be mounted. The dimensions of the panel must be:

Height

19-3/4"

Width

17-27/32"

Thickness

Up to 1/8"

Weight

49 lbs.

SECTION B. CERTIFIED VENT SYSTEMS

REFRIGERATOR

 

 

MODEL

COMPONENTS

PART NO.

 

 

 

RM2191

* RM123 Upper side vent

8030211.331

RM2193

 

 

* RM183 Lower side vent

8030211.332

 

 

 

 

 

** Power Ventilator

3104726.009

 

 

 

* Requires one each

** Alternative instructions forwarded with ventilator kit. Used in conjunction with upper and lower side vents, at minimum vent heights.

SECTION C. OPERATING INSTRUCTIONS

1. IMPORTANCE OF LEVELING A REFRIGERATOR

In an absorption refrigerator system, ammonia is liquefied in the finned condenser coil at the top of the refrigerator. The liquid ammonia then flows into the evaporator (inside the freezer section) and is exposed to a circulating flow of hydrogen gas, which causes the ammonia to evaporate, creating a cold condition in the freezer.

The tubing in the evaporator section is specifically sloped to provide a continuous movement of liquid ammonia downward by gravity through this section. If the refrigera- tor is operated when it is not level and the vehicle is not moving, liquid ammonia will accumulate in sections of the

evaporator tubing. This will slow the circulation of hydro- gen and ammonia gas, or in severe cases, completely block it, resulting in a loss of cooling.

Remember to level the vehicle when stopping for more than an hour, otherwise the cooling unit could be perma- nently damaged due to overheating if it is left "ON".

When the vehicle is moving, the leveling is not critical as the rolling and pitching motion of the vehicle will pass to either side of level, keeping the liquid ammonia from accumulating in the evaporator tubing.

7

Page 7
Image 7
Dometic RM2191 Section B. Certified Vent Systems, Section C. Operating Instructions, Installation of Decorative Door Panel