![Fig.21](/images/new-backgrounds/74409/7440927x1.webp)
14
Replacement of gas/electric equipment complete
1.Remove the covers by removing the screws (1).
2.Disconnect the heater cords at the terminal blocks (note the locations for later relocation).
3.Remove the capillary tube carefully from the evaporator.
4.Remove the screws (2).
5.Release the burner housing from the flue by turning the lever (3) as shown.
6.Pull the equipment out from the cabinet.
1. 1220v115v
240v
_12V
ZI
Fig.21
Disassembly of gas electric/equipment
1.Press the plastic latch (leftwards in Fig. 22).
2.Pull the relay out (if any).
3.Snap off the fuse holder.
4.Press the spring.
5.Pull the
6.Press the gas/electric thermostat left- wards and lift it out.
7.Unscrew the thermocouple from the flame failure safety device.
8.Press the retaining spring for release of thermocouple.
9.Pull out the thermocouple leftwards.
10.Pull the flame failure safety device left and lift it out.
11.Pull off the ignition cord.
12.Snap off the retaining spring.
13.Pull out the igniter.
NOTE: When assembling, always use new
-
for the joints.
2