Dometic RM36O service manual

Models: RM36O

1 19
Download 19 pages 45.03 Kb
Page 12
Image 12
Fig.16Fig . 17

12

5.Remove the screws (2) in fig. 14 and take away the evaporator fin. Remove the screws (3).

6.Remove the connection block (4) cover (Fig. 15) and dis- connect the electrical wires for the heaters.

7.Remove the grounding screw (5).(Fig. 15).

8.Remove the flue and the flue baffle.

9.Remove the screws (6), holding the absorption unit onto the back of the cabinet.

10.Disconnect the burner case by turning the lever

(7)as shown in the picture.

11.Carefully bend absorption unit out of cabinet

(Use a crowbar or similar and a wooden piece as protection when doing this).

12.To replace absorption unit, reverse above procedure.

CAUTION:

1.Be sure to apply sealing permagum (8) on the unit mounting plate (Fig. 16).

2.Be sure to apply proper amount of "Thermal Mas- tic" on the evaporator coil (9).

3.When fitting the evaporator fin be sure to tighten the screws properly in order to obtain a perfect contact between the evaporator coil and evapora- tor flange, otherwise improper cabinet performance may result.

COOLING UNIT REPLACEMENT RM760

The following steps are different from the models RM360, RM460 and RM660.

1.The screws (1) in the freezer should be removed (Fig. 18)

2.The capillary tube should carefully be pulled out from the tube (2).(Fig. 19).

3.When bending the cooling unit out, place the crowbar or similar as well as the wooden protection as shown in the picture.

8 9

Fig.16Fig . 17

Fig.18

Fig.19

Page 12
Image 12
Dometic RM36O service manual