troubleshooting & diagnostic test
Warnings
For information about warnings, refer to the following table. The messages are displayed flashing (alternating between temperature and the message).
Warnings | Information |
|
|
LP | Gas ignition failed. Gas bottle empty or burner jet clogged. |
| |
|
|
Error codes
For information about error codes, refer to the following table. The codes are displayed flashing (alternating between temperature and message).
Error code | Information |
|
|
E 0 | No communication between display and power modules. |
| The control system will revert to full automatic operation selecting the best energy source available with AC, |
| GAS priority. The temperature setting will be maintained at the mid positions. The power module will con- |
| tinually attempt to reestablish operation of the display module. |
|
|
E 1 | Hardware fault in the gas operation system. |
|
|
E 2 | A failure of the temperature sensor device or associated electronic circuitry has occurred. |
| If the connection to the temperature sensor is faulty, the cooling unit runs continuously after 30 seconds delay |
| at power on. |
|
|