Dometic RM460, RM760, RM1300, RM660, RM360 installation instructions Clearances, Examples

Models: RM360 RM460 RM660 RM1300 RM760

1 12
Download 12 pages 26.87 Kb
Page 8
Image 8

CLEARANCES

Minimum clearances in inches to combustible materials are

G:Top 0

K:Side 0

L:Bottom 0

M:Rear 1

Clearance M between the rearmost part of the refngerator and the wall behind the refrigerator

Clearance N on top of the condenser is related to the minimum’ventilation height

See Fig 11 and examples below

Fig. 11

Refrigerator

Overall

 

 

 

Installation

 

 

Recess

 

 

Distance between

 

 

 

 

 

 

 

 

 

model

dimensions

 

dimensions

 

dimensions

 

top of condenser to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

top of refrigerator

 

 

Height

Width

 

Depth

Height

 

Width

Depth

Height

Width

Depth

 

 

 

 

 

 

A

 

B

 

C

h

 

W

d

H

W

D

e

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RM360

30

3/8

21 11/166

 

22 1/16

29 9/16

 

20 1/4

20 3/16

29 3/4

20 1/22

21 3/16

1 1/4

 

RM460

32

15/16623

 

24 11/16632 1/8

 

21 9/16

22 3/4

32 5/16

21 13/16

23 3/4

1 1/4

 

RM660

40

13/16623

 

24 11/166 40

 

21 9/16

22 3/4

40 3/16

21 13/16

23 3/4

1 1/4

 

RM760

52

 

23

 

24 11/166

51 3/16

 

21 9/16

22 3/4

51 3/8

21 13/16

23 3/4

1/8

 

RM1300

57 15/166 24 15/166

24 11/16

57 1/8

 

23 7/16

22 3/4

57 1/2

23 13/16

23 3/4

1/8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EXAMPLES

The clearance N for the RM360 model IS derived at in the following way

Installation with upper and lower side vents

N=Minimum ventilation height 37 minus installation height 29 9/1 6 plus distance between condenser top and refrige- rator top 1 1/4

N=37-29 9/16+1 1/4=8 11/16

Installation with roof vent and lower side vent N=Minimum ventilation height 31 minus installation height 29 9/1 6 plus distance between condenser top and refrigerat- or top 1 1/4 plus distance between roof surface and roof vent cap 5 1/4

N=31-29 9/16+1 1/4+5 1/4=7 15/16