Dometic RMD 8505, RMD 8501 Installation of lower and upper ventilation grilles LS300, R500

Models: RMD 8555 RMD 8551 RMD 8501 RMD 8505

1 24
Download 24 pages 26.19 Kb
Page 12
Image 12
R500

Installation

4.2.1Installation of roof exhaust R500 and lower ventilation grille LS300.

R500

ventilationof H heightMinimum

LS300 ventilationof H heightMinimum

ventilation aperture d = 20 - 40 mm

Fig. 11

Minimum height of ventilation ( mm) H

1.☺☺☺

Roof exhaust R500

Lower vent grille LS300

1250

2.☺☺

Upper vent grille and lower vent grille LS300

1400

3.

Upper vent grille LS300 lower vent grille L205

1400

4.2.2Installation of lower and upper ventilation grilles LS300.

R500

ofventilation

 

LS300

 

 

 

 

Minimum height

 

 

H

 

 

 

 

 

 

 

 

 

 

 

 

LS300

 

 

 

 

 

ventilation aperture d = 20 - 40 mm

Fig. 12

The ventilation grilles must have an open cross-section of at least 400 cm². This is

achieved by using the Dometic LS300 absorber ventilation and air extraction system which has been tested and approved for this purpose.