Installation
4.3Installing the ventilation system
4.3.1Installing LS300
To install the ventilation grilles, cut two rectan- gles width b = b490mm, height a 249mm, in the outer wall of the vehicle (for position of the cuts, see Fig. 11,12).).
Correct mounting of the lower ventilation grille facilitates access to the connections and functional parts during maintenance.
1
Cut two rectangles in the outer wall of the vehicle.
b |
a |
Fig. 13
4.3.2 Installing roof exhaust R500
Measurements of roof exhaust R500
Length Width Height
595 mm | 205 mm 150 mm |
Roof cut out: 87mm X 507 mm
2
Seal the mounting frame making it waterproof (does not apply for mounting frames with integral seal) and screw into position.
14 x
Fig. 14
Fig. 18
3
Insert ventilation grille.
Fig. 15
4
Insert slider.
Fig. 16
5
Lock ventilation grille.
Fig. 17
1
Seal the installation bays and screw them to the vehicle roof.
Fig. 19
2
Place the hood in posti- on and screw it to the installation bays.
Fig. 20
13