ELECTRICAL CONNECTIONS

3.Allow five minutes before restarting after the unit shuts off for any reason. This will avoid damaging the compressor.

4.If your unit has a pump, run the pump drain hose into a sink, toilet, drain, or bucket. Make sure the hose is not kinked. If using a bucket, check and empty the bucket frequently to prevent overflow.

5.Before moving the unit, make sure the pump is empty of wa- ter. To do this, let the unit sit while OFF for 10 minutes, while water drains drain from the coils into the pump. Then push the PURGE switch. When using the DrizAir 80, tip the unit backward to about a 30-degree angle; this will cause the pump impeller to run and empty the collection pan.

6.CAUTION: Check dehumidifier daily for correct operation. Protect floor surfaces from leakage.

Water Removal Rate

With all dehumidifiers, the rate of water removal varies with hu- midity and temperature. If possible, judge the performance of the dehumidifier by how much the humidity drops, rather than by the volume of water being removed and deposited in the bucket. You can roughly guess the humidity by its "feel" on your skin, but to be accurate use a thermo-hygrometer.

To estimate how many dehumidifiers to place, see the Specifica- tions below.

How the Machine Works

DrizAir units are refrigerant dehumidifiers. They operate by blowing moisture-laden air from the room across a cold evapo- rator coil. Moisture in the air condenses on the coil, drips off, and then is removed through a drain hose or pump. Now warmer and drier, the air passes back into the room to continue its work of carrying water vapor.

When a DrizAir Dehumidifier is operating at a room temperature below about 68° F (20° C), frost will normally form on the evapo- rator coil. Water removal will stop temporarily. When an auto- matic control built into the unit senses the ice temperature, it initiates a defrost cycle. During this time, considerable quantities of water drain from the unit. As soon as the ice has melted, nor- mal operation resumes.

How to Use the Touchpad Controller (DrizAir 1200, 2000, 2400 only)

The Touchpad Controller used on DrizAir dehumidifiers has one display and four keys. The normal display messages are:

DEHUMIDIFIER OFF

CMPRSR DELAY 60

DEHUMIDIFIER ON

PUMP PURGING

TOTAL HRS=00000

DEFROST ON

JOB HRS=00000

GET SERVICE ER01

Control Keys

 

ON-OFF. When the unit is first plugged in, the display cycles through three messages: DEHUMIDIFER OFF, TOTAL HOURS , and JOB HOURS. Press the ON-OFF key to turn the unit on. The display often reads CMPRSR DELAY 00, with the numeral counting down from a maximum of 60 seconds to 0. At that point the unit be- gins to operate and the display reads DEHUMIDIFIER ON. (The delay prevents damage from accidental power interruptions, where power to the compressor stops and then starts again when pressure in the system is still high.)

PURGE. Push this key to run the purge before tipping the unit. This empties water from the pump reservoir to prevent leakage. If the unit has been operating, turn the power OFF but leave the cord plugged in for about 10 minutes while water drips from the coil; then press PURGE to remove residual water. The purge also runs automatically every six minutes during operation, and

whenever the reservoir is full. While the purge is running, the display reads PUMP PURGING.

DISPLAY. Press the DISPLAY key to stop the display at DEHUMIDIFER ON or OFF, TOTAL HOURS, or JOB HOURS, when it is cycling. Press again to make the dis- play cycle again.

CLEAR. To clear the JOB HOURS reading, first press the DISPLAY key to make the display read JOB HRS steadily. Then press the CLEAR key to re-set the nu- merals to 00000. NOTE: the TOTAL HOURS reading cannot be re-set.

Defrost On

The display will read DEFROST ON whenever the unit is in a defrost cycle. During normal operation, frost forming on the coils is detected by the temperature sensor, causing a defrost cycle to start. Dehumidification is suspended as hot gas flows through the coils and melts the frost. At the end of the defrost cycle, the display returns to its normal condition.

Changing Language Shown on Display

The default language is English. To change to another language, follow these steps. (1) The unit must be unplugged from the power outlet. Hold down the DISPLAY key while plugging the unit in. The display now reads "ENGLISH." (2) Press the DIS- PLAY key or the CLEAR key to adjust the reading to FRANCAIS, DEUTSCH, or ESPANOL. (3) Then unplug the unit from the power outlet, which sets the language.

CAUTION: While in the change-language mode, pressing other keys can change operating parameters of the unit. Do NOT press other keys or change parameters, except when following guidelines from the Dri-Eaz Service Department.

Error Messages

In case of certain problems, the display may show the error message "GET SERVICE," followed by "ER01" or another nu- meral. Follow these steps:

1.First, unplug the unit and then plug it back in. This may re- set the electronics.

2.If that does not fix the problem, try the solution if one is listed in the table below.

3.If that does not fix the problem, contact the Dri-Eaz Service Department ( contact information above).

ER

Problem with the electronic control panel.

1-2-3-5-6

Contact Service.

 

 

ER4

Problem with temperature sensor or cable.

 

 

ER8

Problem with a touchpad key. Press and release

 

each key several times.

 

 

ER9

Check for obstructions in pump or drain hose, or

 

that pump wiring is correct.

 

 

ELECTRICAL CONNECTIONS

DrizAir Dehumidifiers are designed to operate on a 115V/60 Hz electrical connection. Make sure that the electrical outlet is grounded and that all safety precautions are taken.

MAINTENANCE

Always turn off the power before performing maintenance proce- dures. All the service procedures below are to be executed with the unit unplugged. Perform before each use or as needed.

INSPECT ELECTRICAL SYSTEM: Inspect the electrical cord for damage at regular intervals. Periodically, remove the housing and inspect internal wiring for bare wires, insecure fasteners, and discoloration. Remove and repair any damaged wiring as needed. Failure to do so may lead to electrical shock or a fire hazard.

Copyright 2000, 2002 Dri-Eaz Products, Inc.