SPECIFICATIONS
Model | DRIZAIR 80 and 80 DX | DRIZAIR 1200 | DRIZAIR 2000 LG | DRIZAIR 2400 LG | |||||||
Water Removal, | 80 pints | 38 liters | 123 pints | 58 liters | 198 pints | 94 liters | 240 pints |
| 114 liters | ||
maximum | (10 gallons) |
| (15 gall.) |
| (25 gallons) |
| (30 gallons) |
|
|
| |
Water Removal, | 40 pints | 19 liters | 64 pints | 30 liters | 110 pints | 52 liters | 148 pints |
| 70 liters | ||
AHAM | (5 gallons) |
| (8 gallons) |
| (14 gall) |
| (18.5 gall.) |
|
|
| |
Airflow | 200 cfm | 360 cmh | 225 cfm | 385 cmh | 365 cfm | 700 cmh | 365 cfm |
| 600 cmh | ||
Use Weight | 62 lb (76 DX) | 31 kg (39 DX) | 80 lbs | 36 kg | 132 lbs | 60 kg | 160 lbs |
| 73 kg | ||
Dimensions | 21x14x16 in | 53x36x41 cm | 32x20x20 | 83x50x50 | 41x24x23 | 103x61x57 | 47x24x27 |
| 120x61x6 | ||
| 34x19x20 (DX) | 86x48x51 (DX) | in | cm | in | cm | in |
| 9 cm | ||
Operating range | 55° - 95° F | 13° - 35° C | 33° - 100° F | 0° - 38° C | 33° - 100° F | 0° - 38° C | 33° - 100° F |
| 0° - 38° C | ||
Safety Listings | UL, | UL, | UL, | UL, | |||||||
Filter | Foam |
| Foam or Paper | Foam or Paper | Foam or Paper | ||||||
Defrost | Thermostat – Fan Defrost | Hot Gas Bypass | Hot Gas Bypass | Hot Gas Bypass | |||||||
Pump | Centrifugal (DX only) | Centrifugal | Centrifugal | Centrifugal | |||||||
Refrigerant |
|
|
|
| |||||||
Compressor | 3,926 BTU Reciprocating | 6,670 BTU Rotary | 10,120 BTU Rotary | 13,315 BTU Rotary | |||||||
One dehumidifier will dry the air in APPROXIMATELY the size of the following drying chamber or room(s) with a standard ceiling. | |||||||||||
Soaking wet | 200 sq ft | 20 sq meters | 350 sq ft | 30 sq m | 550 sq ft | 50 sq m | 750 sq ft |
| 70 sq m | ||
Moderately wet | 300 sq ft | 30 sq meters | 500 sq ft | 45 sq m | 825 sq ft | 75 sq m | 1,100 sq ft |
| 100 sq m | ||
Mostly dry | 600 sq ft | 60 sq meters | 1,000 sq ft | 90 sq m | 1650 sq ft | 150 sq m | 2,200 sq ft |
| 200 sq m |
|
Specifications are subject to change without notice. Some values are approximate.
TROUBLESHOOTING
In COLUMN 3, "FS" or Field Solutions can be handled by the technician in the field. Others solutions should be handled by a repair technician – an "AST" or Authorized Service Technician.
WARNING: All the service procedures below should be executed with the power turned off, i.e. unplugged.
|
| See |
|
PROBLEM | CAUSE | above | SOLUTION |
Unit does not operate | No power to machine | FS | Plug in the unit; check power at outlet |
| Switch not turned on | FS | Turn on the switch |
Compressor will not start | Unit needs 5 minutes before | FS | Switch off unit, wait 5 minutes before starting |
| Overload preventing start up | FS | Reduce room temperature below 100° F (38° C) |
| Faulty or broken wire | AST | Replace or repair broken/loose wire |
| Defective relay | AST | Check relay with volt/amp meter |
| Compressor not running | AST | Contact distributor or |
Blower wheel not turning | Obstructed blower | FS | Remove obstruction |
| Loose blower wheel set screw | FS | Tighten set screw |
| Loose or broken wire | AST | Replace broken wire |
| Burned out fan motor | AST | Replace fan motor |
Dehumidifier operating | Not enough time to dry | FS | Allow more time for drying |
but room not dry | Poor air movement | FS | Increase air movement with TurboDryers |
| Excessive air infiltration | FS | Reduce airflow into the area being dried |
Only partial frost | Possible leak in system | AST | Check for leak with gas leak detector |
or moisture on coils | Low charge in system | AST | Repair and recharge system |
No moisture | Possible leak in system | AST | Check for leak with gas leak detector |
or frost on coils | Capillary tubing damaged | AST | Look for damage, replace tubing |
| Compressor not running | AST | Contact distributor or |
Unit continuously in defrost | Room temperature too low | FS | Increase room temperature |
| Defective control assembly | AST | Replace control assembly |
| Defective bypass relay valve | AST | Replace bypass valve |
Unit does not defrost | Defective sensor | AST | Replace sensor |
(heavy frost or ice | Defective control assembly | AST | Replace control assembly |
persists over several hours) | Defective bypass relay valve | AST | Replace bypass valve |
Unit collects little water | Room air too dry | FS | Check humidity with a hygrometer |
| Room temperature too low | FS | Increase the room temperature |
| Airflow through unit restricted | FS | Increase airflow; clean filter and coils |
Pump does not function | Stuck float valve | FS | Clean float valve shaft |
FOR PARTS AND SERVICE CALL YOUR LOCAL DISTRIBUTOR, or the
Copyright 2000, 2002 | 4 |