2.5. LIGHTING PROCEDURE
a. Fill hopper and clean burn pot.
b. Press “MODE” button to select the desired setting “MANUAL” or “THERMOSTAT”
c. Adjust feed rate to desired setting by pressing “-” or “+” button.
If fire doesn‟t start in 35 minutes, a warning code will appear. Refer to troubles hooting section for more
details.
2.6. UNIT CONTROLS (See Figure 16)
The blowers and automatic fuel supply are controlled from a panel on the right-hand side of the ECO-6 5. The
control panel functions are as follows.
a. MODE SWITCH
When the mode switch is press ed, you will be able
to choose the Manual or the Therm ostat mode, or
to turn off the appliance. If the Manual mode is
selected, the stove will automatically ignite. At this
time, the heat level m ust be selected manually to
adjust the stove‟s heat output to the desired level.
If the thermostat mode is selected, the stove will
automatically modulate between the lowest heat
level and the heat level selected to keep the room
temperature at the thermostat‟s setting. If the set
room temperature is achieved while th e stove has
been running at the lowest heat level for m ore
than 45 minutes, the unit will autom atically shut off
and will start another ignition cycle only when the
thermostat calls for heat again. No f ire starter is
necessary to ignite the unit. The auger will feed
fuel and the electronic igniter will start. If the unit
doesn‟t ignite within 12 minutes, the stove will start
another ignition cycle. If ignition fails a second
time, a warning message will appear on the
control panel.
The Heat Level may be selected during the
ignition cycle. However, the unit will onl y feed fuel
at the desired heat level setting when the heat
sensor located into the s tove will receive a signal
indicating that the unit has been fully ignited. This
may take anywhere between 10 and 15 minutes.
b. FUEL FEED SWITCH
When the “Fuel Feed” button is pushed the stove
will feed pellets continuously into the burn pot
during 1 minute.
CAUTION: THIS FUNCTION CAN ONLY BE
OPERATED WHEN THE STOVE I S IN “OFF”
POSITION. THE FUEL FEED SWITCH IS USED TO
PRIME THE AUGER WHEN AUGER IS EMPTY.
FIGURE 17
PC board