Drolet Jurassien, Savannah, ElDorado Clearances From Combustibles, Single pipe / Double pipe

Models: ElDorado Savannah Adirondack Jurassien Celtic

1 26
Download 26 pages 60.16 Kb
Page 11
Image 11
CLEARANCES FROM COMBUSTIBLES

CLEARANCES FROM COMBUSTIBLES

It is of outmost importance that the clearances to combustible materials be scrupulously respected upon installation of the stove you have selected. Refer to the tables below :

 

 

 

Single pipe / Double pipe

 

Model

A

B

C

D

E

F

Eldorado

15/6

18/18

12/12

21.5/12.5

30.5/30.5

24/24

Adirondack

15/5

12/12

10/8

21.5/11.5

24.5/24.5

22/20

Savannah

15/6

18/18

12/12

21.5/12.5

30.5/30.5

24/24

Celtic

15/5

12/12

10/8

21.5/11.5

24.5/24.5

22/20

Jurassien

14/7

8/8

10/6

20.8/13.7

23.5/23.5

22.2/18.2

Floor to ceiling height must be at least 7' (84") in all cases.

The clearance between the flue pipe and a wall are valid only for vertical walls and for vertical flue pipe.

The flue pipe must not go through roof trussing, an attic, a wardrobe, a floor, a combustible partition, or similar spaces.

A flue pipe crossing a combustible wall must have a minimum clearance of 18".

To reduce flue pipe clearances from combustible materials, contact your local safety department.