CONNECTION Natural Gas Grills

Check:

1) Gas supply hose-to-manifold connection.

WARNING: If there is a leak at connection (1), retighten the fitting with a wrench and recheck for leaks with soap and water solution. If a leak persists after retightening the fitting, turn off the gas. DO NOT OPERATE THE GRILL. Contact the Customer Service Representative in your area by calling 1-800-382-2637.

2)Hose to quick disconnect connection.

3)Valves-to-manifold connections.

WARNING: If there is a leak at connections (2) or (3), turn off the gas. DO NOT OPERATE THE GRILL. Contact the Customer Service Representative in your area by calling 1-800-382-2637.

When leak checks are complete, turn gas supply off at the source and rinse connections with water.

3100/4100

Check:

 

1) Side burner hose to side burner valve.

 

2) Gas supply hose-to-manifold connection.

3200/4200

 

WARNING: If there is a leak at connection (1) or (2), retighten

 

the fitting with a wrench and recheck for leaks with soap and

 

water solution. If a leak persists after retightening the fitting,

 

turn off the gas. DO NOT OPERATE THE GRILL. Contact the

 

Customer Service Representative in your area by calling

 

1-800-382-2637.

 

3) Hose to quick disconnect connection.

 

4) Valves-to-manifold connections.

 

WARNING: If there is a leak at connections (3) or (4), turn

 

off the gas. DO NOT OPERATE THE GRILL. Contact the

 

Customer Service Representative in your area by calling

 

1-800-382-2637.

 

When leak checks are complete, turn gas supply OFF at the source and rinse

 

connections with water.

 

Re-install Control Panel

 

Follow ‘Remove Control Panel’ steps in reverse. Make sure all screws are secure.

 

18

www.ducane.com

Page 18
Image 18
Ducane 41-4200, 31-3200, Affinity Natural Gas Grill owner manual Check, Re-install Control Panel