![Manual background](/images/new-backgrounds/44135/441359x1.webp)
2AC14 Split System Air Conditioner 14
Cooling Performance with Air Handlers & Furnaces 36, 42, 48, 60
| Indoor Model |
|
|
|
|
|
| |
Outdoor |
|
| Variable |
|
| Rated | Rated |
|
|
|
|
|
| ||||
|
| Speed | SEER | EER | ARI | Sensible | CFM | |
Model |
|
| ||||||
|
| Furnace |
|
| Capacity1 | Capacity |
| |
| Piston or Field | Factory |
|
|
| |||
|
|
|
|
|
|
| ||
| Installed TXV | Installed TXV |
|
|
|
|
|
|
| RBCS2M36C****P+TXV | RBCS2M36C****T | 14.00 | 12.50 | 34,800 | 25,400 | 1250 | |
| RBCS2M36V****P+txV | 15.00 | 13.50 | 35,000 | 25,600 | 1250 | ||
| E(C,H,M,U)1P36NB+TXV | E(C,H,M,U)2T36NB | CMPEV100 | 15.00 | 13.00 | 34,600 | 25,200 | 1250 |
| E(C,H,M,U)1P36NB+TXV | E(C,H,M,U)2T36NB | MPGAV100 | 15.00 | 13.00 | 34,600 | 25,200 | 1250 |
2AC14**36P |
|
|
|
|
|
|
|
|
| E(C,H,M,U)1P43NB+TXV | E(C,H,M,U)2T43NB | CMPEV100 | 15.00 | 13.50 | 34,800 | 25,400 | 1250 |
| E(C,H,M,U)1P43NB+TXV | E(C,H,M,U)2T43NB | MPGAV100 | 15.00 | 13.50 | 34,800 | 25,400 | 1250 |
| E(C,M,U)1P36NA+TXV | E(C,M,U)2T36NA | CMPEV050,075 | 15.00 | 13.00 | 34,600 | 25,300 | 1250 |
| E(C,M,U)1P36NA+TXV | E(C,M,U)2T36NA | MPGAV050,075 | 15.00 | 13.00 | 34,600 | 25,300 | 1250 |
| RBCS2M42C****P+TXV | RBCS2M42C*****T | 14.00 | 12.00 | 40,000 | 29,200 | 1450 | |
| RBCS2M42V****P+txV | 15.00 | 13.00 | 40,500 | 29,565 | 1450 | ||
| E(C,H,U)1P49NC+TXV | E(C,H,U)2T49NC | CMPEV0125 | 15.00 | 13.00 | 40,000 | 29,200 | 1450 |
2AC14*42P |
|
|
|
|
|
|
|
|
| E(C,H,U)1P49NC+TXV | E(C,H,U)2T49NC | MPGAV0125 | 15.00 | 13.00 | 40,000 | 29,200 | 1450 |
| E(C,H,U)1P62NC+TXV | E(C,H,U)2T62NC | CMPEV125 | 15.00 | 13.00 | 40,000 | 29,200 | 1450 |
| E(C,H,U)1P62NC+TXV | E(C,H,U)2T62NC | MPGAV125 | 15.00 | 13.00 | 40,000 | 29,200 | 1450 |
| RBCS2M48C****P+TXV | RBCS2M48C*****T | 14.50 | 12.50 | 48,000 | 34,600 | 1650 | |
| RBCS2M48V****P+txV | 15.00 | 13.00 | 48,000 | 34,600 | 1650 | ||
| E(C,H,U)1P49NC+TXV | E(C,H,U)2T49NC | CMPEV125 | 14.50 | 12.50 | 48,000 | 34,600 | 1650 |
2AC14*48P |
|
|
|
|
|
|
|
|
| E(C,H,U)1P49NC+TXV | E(C,H,U)2T49NC | MPGAV125 | 14.50 | 12.50 | 48,000 | 34,600 | 1650 |
| E(C,H,U)1P62NC+TXV | E(C,H,U)2T62NC | CMPEV125 | 14.50 | 12.50 | 54,000 | 34,600 | 1650 |
| E(C,H,U)1P62NC+TXV | E(C,H,U)2T62NC | MPGAV125 | 14.50 | 12.50 | 54,000 | 34,600 | 1650 |
| RBCS2M60V****P+TXV | 14.00 | 12.00 | 54,000 | 41,600 | 1950 | ||
2AC14*60P |
|
|
|
|
|
|
|
|
| E(C,H,U)1P62NC+TXV | E(C,H,U)2T62NC | MPGAV125 | 13.50 | 11.50 | 54,000 | 41,600 | 1950 |
|
|
|
|
|
|
|
|
|
| Refrigerant |
| Refrigerant | |||
| Connection |
| Line Size | |||
Outdoor |
| Indoor | Suction |
| ||
|
| |||||
|
|
|
|
| Liquid | |
Suction | Liquid |
| Suction | Liquid | ||
3/4 | 3/8 |
| 3/4 | 3/8 | 3/4 | 3/8 |
3/4 | 3/8 |
| 3/4 | 3/8 | 3/4 | 3/8 |
3/4 | 3/8 |
| 3/4 | 3/8 | 3/4 | 3/8 |
3/4 | 3/8 |
| 3/4 | 3/8 | 3/4 | 3/8 |
3/4 | 3/8 |
| 3/4 | 3/8 | 3/4 | 3/8 |
3/4 | 3/8 |
| 3/4 | 3/8 | 3/4 | 3/8 |
3/4 | 3/8 |
| 3/4 | 3/8 | 3/4 | 3/8 |
3/4 | 3/8 |
| 3/4 | 3/8 | 3/4 | 3/8 |
7/8 | 3/8 |
| 7/8 | 3/8 | 7/8 | 3/8 |
7/8 | 3/8 |
| 7/8 | 3/8 | 7/8 | 3/8 |
7/8 | 3/8 |
| 7/8 | 3/8 | 7/8 | 3/8 |
7/8 | 3/8 |
| 7/8 | 3/8 | 7/8 | 3/8 |
7/8 | 3/8 |
| 7/8 | 3/8 | 7/8 | 3/8 |
7/8 | 3/8 |
| 7/8 | 3/8 | 7/8 | 3/8 |
7/8 | 3/8 |
| 7/8 | 3/8 | 7/8 | 3/8 |
7/8 | 3/8 |
| 7/8 | 3/8 | 7/8 | 3/8 |
7/8 | 3/8 |
| 7/8 | 3/8 | 7/8 | 3/8 |
7/8 | 3/8 |
| 7/8 | 3/8 | 7/8 | 3/8 |
7/8 | 3/8 |
| 7/8 | 3/8 | 7/8 | 3/8 |
7/8 | 3/8 |
| 7/8 | 3/8 | 7/8 | 3/8 |
7/8 | 3/8 |
| 7/8 | 3/8 | 3/8 | |
7/8 | 3/8 |
| 7/8 | 3/8 | 3/8 | |
|
|
|
|
|
|
|
Indoor
Metering
Device
Req'd | Optional | |
Field | ||
Indoor2 | ||
Orifice | Installed | |
Orifice | ||
|
---A2TXV01
---A2TXV01
---A2TXV01
---A2TXV01
---A2TXV01
---A2TXV01
---A2TXV01
---A2TXV01
---A2TXV02
---A2TXV02
---A2TXV02
---A2TXV02
---A2TXV02
---A2TXV02
---A2TXV02
---A2TXV02
---A2TXV02
---A2TXV02
---A2TXV02
---A2TXV02
---A2TXV02
---A2TXV02
**= B, L, BC, LC
*= B, L
1Certified in accordance with Unitary Air Conditioner Certification Program, which is based on ARI Standard 210/240. 2Required to achieve ARI rating.
A blower time delay is required to achieve ARI rating. This feature is standard on all Allied Air Enterprises furnace and air handler products.