2AC14 Split System Air Conditioner 14
Cooling Performance with Evaporator Coils
Outdoor
Model
2AC14**18P
2AC14**24P
2AC14**30P
2AC14**36P
2AC14*42P
2AC14*48P
2AC14*60P
| Indoor Model |
|
|
|
|
|
|
| Refrigerant |
| Refrigerant | ||||
|
|
|
|
|
|
|
| Connection |
| Line Size | |||||
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
| SEER | EER | Rated | Rated | CFM | Outdoor |
| Indoor |
|
| ||
|
|
|
|
|
|
| |||||||||
|
|
|
| ARI | Sensible |
| Suction | Liquid | |||||||
| Piston or Field |
| Factory |
|
| Capacity1 | Capacity |
| Suction | Liquid |
| Suction | Liquid | ||
|
|
|
|
|
|
|
|
|
|
|
| ||||
| Installed TXV | Installed TXV |
|
|
|
|
|
|
|
|
|
|
|
| |
E(C,H,M,U)1P23N(A,B)+TXV | E(C,H,M,U)2T23N(A,B) | 14.00 | 12.00 | 19,000 | 12,900 | 650 | 3/4 | 3/8 |
| 3/4 | 3/8 | 3/4 | 3/8 | ||
E(C,M,U)1P24N(A,B)+TXV | E(C,M,U)2T24NA | 13.50 | 12.00 | 18,400 | 12,500 | 650 | 3/4 | 3/8 |
| 3/4 | 3/8 | 3/4 | 3/8 | ||
| E(C,H,M,U)1P23N(A,B) | E(C,H,M,U)2T23N(A,B) | 14.00 | 12.50 | 23,600 | 17,600 | 850 | 3/4 | 3/8 |
| 3/4 | 3/8 | 3/4 | 3/8 | |
| E(C,H,M,U)1P29NA+TXV | E(C,H,M,U)2T29NA | 14.00 | 12.50 | 23,800 | 17,600 | 850 | 3/4 | 3/8 |
| 3/4 | 3/8 | 3/4 | 3/8 | |
E(C,M,U)1P24N(A,B)+TXV | E(C,M,U)2T24NA | 13.50 | 12.00 | 22,600 | 16,700 | 845 | 3/4 | 3/8 |
| 3/4 | 3/8 | 3/4 | 3/8 | ||
E(C,H,M,U)1P36N(A,B,C)+TXV | E(C,H,M,U)2T36N(A,B,C) | 14.00 | 12.00 | 28,600 | 20,900 | 1050 | 3/4 | 3/8 |
| 3/4 | 3/8 | 3/4 | 3/8 | ||
E(C,H,M,U)1P36N(A,B,C)+TXV | E(C,H,M,U)2T36N(A,B,C) | 14.00 | 12.00 | 34,600 | 25,300 | 1250 | 3/4 | 3/8 |
| 3/4 | 3/8 | 3/4 | 3/8 | ||
| E(C,H,M,U)1P43NB+TXV | E(C,H,M,U)2T43B | 14.50 | 12.50 | 34,800 | 25,400 | 1250 | 3/4 | 3/8 |
| 7/8 | 3/8 | 3/4 | 3/8 | |
| E(C,H,U)1P49NC+TXV | E(C,H,U)2T49NC | 14.00 | 12.00 | 40,000 | 29,200 | 1450 | 7/8 | 3/8 |
| 7/8 | 3/8 | 7/8 | 3/8 | |
| E(C,H,U)1P62NC+TXV | E(C,H,U)2T62NC | 14.00 | 11.50 | 40,000 | 29,200 | 1450 | 7/8 | 3/8 |
| 7/8 | 3/8 | 7/8 | 3/8 | |
| E(C,H,U)1P62ND+TXV | E(C,H,U)2T62ND | 14.00 | 12.00 | 40,000 | 29,200 | 1450 | 7/8 | 3/8 |
| 7/8 | 3/8 | 7/8 | 3/8 | |
| E(C,H,U)1P49NC+TXV | E(C,H,U)2T49NC | 14.00 | 12.00 | 48,000 | 34,500 | 1650 | 7/8 | 3/8 |
| 7/8 | 3/8 | 7/8 | 3/8 | |
| E(C,M,U)1P62NC+TXV | E(C,H,U)2T62NC | 14.00 | 12.00 | 48,000 | 34,500 | 1650 | 7/8 | 3/8 |
| 7/8 | 3/8 | 7/8 | 3/8 | |
| E(C,H,U)1P62ND+TXV | E(C,H,U)2T62ND | 14.00 | 12.00 | 48,000 | 34,500 | 1650 | 7/8 | 3/8 |
| 7/8 | 3/8 | 7/8 | 3/8 | |
| E(C,H,U)1P62NC+TXV | E(C,H,U)2T62NC | 13.00 | 11.00 | 53,500 | 41,200 | 1950 | 7/8 | 3/8 |
| 7/8 | 3/8 | 3/8 | ||
| E(C,H,U)1P62ND+TXV | E(C,H,U)2T62ND | 13.00 | 11.00 | 53,000 | 40,800 | 1950 | 7/8 | 3/8 |
| 7/8 | 3/8 | 3/8 | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
** | = B, L, BC, LC | 1 | Certified in accordance with Unitary Air Conditioner Certification Program, which is based on ARI Standard 210/240. | ||||||||||||
* | = B, L | 2 | Required to achieve ARI rating. |
|
|
|
|
|
|
|
|
|
|
A blower time delay is required to achieve ARI rating.
Indoor
Metering
Device
Req'd | Optional |
Indoor2 | Field |
Orifice | Installed |
| Orifice |
---A2TXV01
---A2TXV01
---A2TXV01
---A2TXV01
---A2TXV01
---A2TXV01
---A2TXV01
---A2TXV01
---A2TXV02
---A2TXV02
---A2TXV02
---A2TXV02
---A2TXV02
---A2TXV02
---A2TXV02
---A2TXV02