| 14 | 2AC14 Split System Air Conditioner |
Cooling Performance with Air Handlers & Furnaces 18, 24, 30
| Indoor Model |
|
|
|
|
|
|
| Refrigerant |
| Refrigerant | |||
|
|
|
|
|
|
|
| Connection |
| Line Size | ||||
|
|
|
|
|
|
|
|
|
|
| ||||
Outdoor |
|
| Variable |
|
| Rated | Rated |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
| Speed | SEER | EER | ARI | Sensible | CFM |
|
|
|
|
|
| |
Model |
|
| Outdoor | Indoor |
|
| ||||||||
|
| Furnace |
|
| Capacity1 | Capacity |
| Suction |
| |||||
| Piston or Field | Factory |
|
|
| Suction | Liquid | Suction | Liquid | Liquid | ||||
|
|
|
|
|
|
| ||||||||
| Installed TXV | Installed TXV |
|
|
|
|
|
|
|
|
|
|
|
|
| RBCS2M18C****P+TXV | RBCS2M18C****T | 14.50 | 12.50 | 19,000 | 12,900 | 650 | 3/4 | 3/8 | 3/4 | 3/8 | 3/4 | 3/8 | |
| RBCS2M24V****P+txV | 15.00 | 13.50 | 19,000 | 12,900 | 650 | 3/4 | 3/8 | 3/4 | 3/8 | 3/4 | 3/8 | ||
| E(C,H,M,U)1P23NA+TXV | E(C,H,M,U)2T23NA | CMPEV050,075 | 15.00 | 13.00 | 19,000 | 12,900 | 650 | 3/4 | 3/8 | 3/4 | 3/8 | 3/4 | 3/8 |
2AC14**18P |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| E(C,H,M,U)1P23NA+TXV | E(C,H,M,U)2T23NA | MPGAV050,075 | 15.00 | 13.00 | 19,000 | 12,900 | 650 | 3/4 | 3/8 | 3/4 | 3/8 | 3/4 | 3/8 |
| E(C,M,U)1P24NA+TXV | E(C,M,U)2T24NA | CMPEV050,075 | 15.00 | 13.00 | 18,400 | 12,500 | 650 | 3/4 | 3/8 | 3/4 | 3/8 | 3/4 | 3/8 |
| E(C,M,U)1P24NA+TXV | E(C,M,U)2T24NA | MPGAV050,075 | 15.00 | 13.00 | 18,400 | 12,500 | 650 | 3/4 | 3/8 | 3/4 | 3/8 | 3/4 | 3/8 |
| RBCS2M24C****P+TXV | RBCS2M24C*****T | 14.50 | 12.50 | 23,800 | 17,600 | 850 | 3/4 | 3/8 | 3/4 | 3/8 | 3/4 | 3/8 | |
| RBCS2M24V****P+txV | 15.00 | 13.50 | 24,000 | 17,600 | 850 | 3/4 | 3/8 | 3/4 | 3/8 | 3/4 | 3/8 | ||
| E(C,H,M,U)1P23NA+TXV | E(C,H,M,U)2T23NA | CMPEV050,075 | 15.00 | 13.50 | 23,600 | 17,500 | 850 | 3/4 | 3/8 | 3/4 | 3/8 | 3/4 | 3/8 |
| E(C,H,M,U)1P23NA+TXV | E(C,H,M,U)2T23NA | MPGAV050,075 | 15.00 | 13.50 | 23,600 | 17,500 | 850 | 3/4 | 3/8 | 3/4 | 3/8 | 3/4 | 3/8 |
2AC14**24P |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| E(C,HM,U)1P29NA+TXV | E(C,M,U)2T29NA | CMPEV050,075 | 15.00 | 13.50 | 23,800 | 17,600 | 850 | 3/4 | 3/8 | 3/4 | 3/8 | 3/4 | 3/8 |
| E(C,HM,U)1P29NA+TXV | E(C,M,U)2T29NA | MPGAV050,075 | 15.00 | 13.50 | 23,800 | 17,600 | 850 | 3/4 | 3/8 | 3/4 | 3/8 | 3/4 | 3/8 |
| E(C,M,U)1P24NA+TXV | E(C,M,U)2T24NA | CMPEV050,075 | 15.00 | 13.00 | 22,600 | 16,700 | 845 | 3/4 | 3/8 | 3/4 | 3/8 | 3/4 | 3/8 |
| E(C,M,U)1P24NA+TXV | E(C,M,U)2T24NA | MPGAV050,075 | 15.00 | 13.00 | 22,600 | 16,700 | 845 | 3/4 | 3/8 | 3/4 | 3/8 | 3/4 | 3/8 |
| RBCS2M30C****P+TXV | RBCS2M30C*****T | 14.00 | 12.50 | 28,600 | 20,900 | 1050 | 3/4 | 3/8 | 3/4 | 3/8 | 3/4 | 3/8 | |
| RBCS2M36V****P+txV | 15.00 | 13.50 | 29,000 | 21,200 | 1050 | 3/4 | 3/8 | 3/4 | 3/8 | 3/4 | 3/8 | ||
| E(C,HM,U)1P36NB+TXV | E(C,HM,U)2T36NB | CMPEV100 | 15.00 | 13.00 | 28,600 | 20,900 | 1050 | 3/4 | 3/8 | 3/4 | 3/8 | 3/4 | 3/8 |
2AC14**30P |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| E(C,HM,U)1P36NB+TXV | E(C,HM,U)2T36NB | MPGAV100 | 15.00 | 13.00 | 28,600 | 20,900 | 1050 | 3/4 | 3/8 | 3/4 | 3/8 | 3/4 | 3/8 |
| E(C,M,U)1P36NA+TXV | E(C,M,U)2T36NA | CMPEV050,075 | 15.00 | 13.00 | 28,600 | 20,900 | 1050 | 3/4 | 3/8 | 3/4 | 3/8 | 3/4 | 3/8 |
| E(C,M,U)1P36NA+TXV | E(C,M,U)2T36NA | MPGAV050,075 | 15.00 | 13.00 | 28.600 | 20,900 | 1050 | 3/4 | 3/8 | 3/4 | 3/8 | 3/4 | 3/8 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
** | = B, L, BC, LC | 1Certified in accordance with Unitary Air Conditioner Certification Program, which is based on ARI Standard 210/240. |
* | = B, L | 2Required to achieve ARI rating. |
|
| A blower time delay is required to achieve ARI rating. This feature is standard on all Allied Air Enterprises furnace and |
|
| air handler products. |
Indoor
Metering
Device
Req'd | Optional | |
Field | ||
Indoor2 | ||
Orifice | Installed | |
Orifice | ||
|
---A2TXV01
---A2TXV01
---A2TXV01
---A2TXV01
---A2TXV01
---A2TXV01
---A2TXV01
---A2TXV01
---A2TXV01
---A2TXV01
---A2TXV01
---A2TXV01
---A2TXV01
---A2TXV01
---A2TXV01
---A2TXV01
---A2TXV01
---A2TXV01
---A2TXV01
---A2TXV01