Xantrex Technology HF 1000 Electrical Specifications Inverter Mode, DC Input, Freedom HF, Other

Models: HF 1800 HF 1000

1 78
Download 78 pages 18.24 Kb
Page 62
Image 62
Electrical Specifications: Inverter Mode

Electrical Specifications: Inverter Mode

DC Input

Freedom HF 1000

Freedom HF 1800

 

 

 

Operating voltage range

10.5V–15.5V

10.5V–15.5V

 

 

 

Safe non-operating voltage range

0–16 Vdc

0–16 Vdc

 

 

 

Normal voltage

12.5V

12.5V

 

 

 

Nominal current at full load

100A

180A

AC Output

Freedom HF 1000

Freedom HF 1800

 

 

 

Output voltage

115 Vac

115 Vac

 

 

 

Continuous power

1.0kW @ 25 °C

1.8kW @ 25 °C

 

 

 

Surge power

17A

30A

 

(2kW for 200 ms)

(3.6kW for 300 ms)

 

 

 

Max short-circuit current

55A peak

55A peak

 

 

 

Frequency

60 Hz

60 Hz

 

 

 

Wave shape

Modified Sinewave

Modified Sinewave

 

 

Power derating above 40 °C ambient

See “Invert Power Derating vs. Ambient

temp

Temperature” on page A–6.

 

 

 

Peak efficiency

≥87%

≥87%

 

 

 

Full load efficiency

≥80%

≥80%

Other

Freedom HF 1000

Freedom HF 1800

 

 

 

No load input power (producing

≤10W

≤10W

output voltage)

 

 

 

 

 

Off mode current draw

≤1mA

≤1mA

A–2