Battery Charging Status LED

Table 4-2below illustrates the battery charging status as shown on the

Status LED and display screen.

Table 4-2

Battery Charging Status LED

 

 

 

 

 

 

Status LED

 

 

Display Screen

 

 

Condition

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Solid GREEN

 

 

FUL

 

 

 

Battery is FULL.

 

 

 

 

 

 

 

 

 

 

 

Flashing GREEN

 

 

BULCHg12.8

 

 

Battery is in BULK CHARGE.

 

 

 

 

 

(where 12.8 is an example of battery voltage)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ABSCHg14.2

 

 

Battery is in ABSORPTION

 

 

 

 

 

(where 14.2 is an example of battery voltage)

CHARGE.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Solid RED

 

 

 

E10 to e12

 

 

 

See Table 5-1, “Error Codes

 

 

 

 

 

 

 

 

 

 

Displayed on the Display Panel

 

 

 

 

 

 

 

 

 

 

Screen” on page 5–5.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 4-3below illustrates the battery charging voltage and current

 

 

 

 

settings.

 

 

 

 

 

 

 

Table 4-3

Battery Charging Voltage and Current Settings

 

 

 

 

Battery Type

 

Bulk/Absorption

 

Float Voltage

 

Charge Current

 

Float Current

 

 

 

 

 

 

 

 

 

Voltage (Volts)

 

(Volts)

 

(Amps)

 

(Amps)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Flooded

 

 

14.4

 

 

13.5

 

2

 

 

2

 

 

 

 

 

 

 

 

 

5, 10, 20

 

2

 

 

 

 

 

 

 

 

 

40

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GEL

 

 

14.2

 

 

13.8

 

2

 

 

2

 

 

 

 

 

 

 

 

 

5, 10, 20

 

2

 

 

 

 

 

 

 

 

 

40

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AGM

 

 

14.3

 

 

13.4

 

2

 

 

2

 

 

 

 

 

 

 

 

 

5, 10, 20

 

2

 

 

 

 

 

 

 

 

 

40

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

Fixed

 

 

13.5

 

 

13.5

 

2, 5, 10, 20, 40

 

2, 5, 10, 20, 40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4–12

975-0390-01-01