Thermostat

The room thermostat should be located on an inside wall where it will not be subject to drafts, sun exposure, or heat from electrical fixtures or appliances. Follow the manufacturer’s instructions enclosed with thermostat for general installation procedure. Color-coded insulated wires (#18 AWG) should be used to connect thermostat to unit. Four wires are required for cooling.

Compressor

Units are shipped with compressor mountings factory- adjusted and ready for operation. Caution: Do not loosen compressor mounting bolts.

Heater Kit Accessory (if used)

The unit is fully equipped for cooling operation without auxiliary heat. A heater kit accessory may also be used.

To install the heater kit accessory (see Figure 7):

1.Disconnect the power and remove the heater compart- ment access panel.

2.Disconnect the plug separating the high voltage wire harness. Remove the high voltage wire harness plug and discard.

3.Remove the heater blockoff by removing the four screws holding it in place.

4.Insert the heater into the control panel and fasten in the same mounting holes.

5.Plug the heater wiring harness into the wire harness on the control assembly. Field wiring of the auxiliary heater is separate from the unit power supply. Wire the power supply wiring for the heater to the appropriate connections on the heater kit.

6.Replace the heater compartment access panel and reconnect the power.

Removal of Unit from Common Venting System

When an existing furnace is removed from a common venting system serving other appliances, the venting system is likely to be too large to properly vent the remaining attached appliances.The following test should be conducted with each appliance while the other appliances connected to the common venting system are not in operation.

1.Seal any unused openings in the common venting system.

2.Visually inspect the venting system for proper size and horizontal pitch and determine there is no block-

Heater Kit Accessory Installation

Heater

Blockoff

Heater

Compartment

Access

Panel

Heater Kit

Figure 7

age or restriction, leakage, corrosion, or other deficien- cies which could cause an unsafe condition.

3.Insofar as is practical, close all building doors and windows between the space in which the appliances remaining connected to the common venting system are located and other spaces in the building. Turn on clothes dryers and any appliance not connected to the common venting system. Turn on exhaust fans, such as range hoods and bathroom exhausts, so they will operate at maximum speed. Do not operate a summer exhaust fan. Close fireplace dampers.

4.Following the lighting instructions, place the unit being inspected in operation. Adjust the thermostat so the appliance will operate continuously.

5.Test for spillage at the draft control relief opening after 5 minutes of main burner operation. Use the flame of a match or candle.

6.Follow the preceding steps for each appliance con- nected to the common venting system.

7.After it has been determined that each appliance remaining connected to the common venting system properly vents when tested as outlined above, return doors, windows, exhaust fans, fireplace dampers, and any other fuel burning appliance to their previous condition of use.

8.If improper venting is observed during any of the

above tests, the common venting system must be corrected. See National Fuel Gas Code, ANSI

Z223.1 (latest edition) or CAN/CGA B149.1 & .2 Canadian Installation Codes to correct improper operation of common venting system.

Page 6

# 48369K005

Page 6
Image 6
Ducane (HVAC) (2/4)SH13 warranty Heater Kit Accessory Installation, Thermostat, Compressor, Heater Kit Accessory if used

(2/4)SH13 specifications

The Ducane (HVAC) 2/4SH13 is a versatile heat pump designed to provide efficient heating and cooling solutions for residential and light commercial applications. Renowned for its reliability and performance, the 2/4SH13 units come equipped with advanced features that ensure a comfortable indoor environment throughout the year.

One of the standout characteristics of the Ducane 2/4SH13 is its impressive Seasonal Energy Efficiency Ratio (SEER) and Heating Seasonal Performance Factor (HSPF) ratings. With a high SEER rating, the heat pump maximizes cooling efficiency, resulting in lower energy bills and reduced environmental impact. The HSPF rating also highlights its effectiveness in heating mode during colder months. This combination of efficiency and effectiveness makes the 2/4SH13 an excellent choice for homeowners looking to minimize energy consumption.

The 2/4SH13 utilizes a scroll compressor, which is recognized for its quiet operation and reliability. This type of compressor works efficiently under various load conditions and contributes to the overall longevity of the unit. Additionally, the heat pump is equipped with a durable cabinet that features a baked-on powder coat finish, ensuring protection against the elements and prolonging the life of the system.

For enhanced comfort, the Ducane 2/4SH13 employs a two-stage heating system that provides consistent heating performance during fluctuating temperatures. This capability minimizes the temperature swings often associated with single-stage systems, allowing for a more stable and comfortable indoor climate.

Furthermore, the heat pump integrates advanced refrigerant management technology, utilizing environmentally friendly R-410A refrigerant. This refrigerant not only meets current environmental regulations but also supports improved system efficiency and lower refrigerant leakage.

Installation and maintenance of the Ducane 2/4SH13 are straightforward, thanks to its compact design and accessible service panels. The unit’s compatibility with smart thermostats allows homeowners to achieve optimal control over their heating and cooling schedules, further enhancing energy savings.

Ducane backs the 2/4SH13 with a robust warranty, providing peace of mind for customers who invest in this efficient heat pump solution. Overall, the Ducane 2/4SH13 stands out in the HVAC market for its blend of efficiency, reliability, and user-friendly features, making it a preferred choice for many seeking optimal indoor comfort.