Ducane (HVAC) RLBF/R80C warranty Model Number Guide, Physical and Electrical

Models: RLBF/R80C

1 6
Download 6 pages 52.16 Kb
Page 2
Image 2
Model Number Guide

Model Number Guide

R

L

BF

80

C 84/95 D

16 - 2A

Product Family

L - Oil

BR-Basement Rear Flue BF-Basement Front Flue

80-80% AFUE

C - Series

Revision Code

CFM X 100

D - Direct Drive B - Belt Drive

Nominal Output 95 - 95,000 Btuh

Physical and Electrical

 

 

 

 

 

 

 

 

 

Max.

 

 

 

 

 

 

 

Nom.

Flue

Filter

 

Time

 

 

 

Nozzle

Input

Output

 

Volts/

Delay

Trans.

Weight

Model

AFUE

Cooling

Dia.

Size

Size

(Btuh)

(Btuh)

Hz/Phase

Breaker

(V.A.)

(lb.)

 

 

 

 

 

Cap.

(in.)

(in.)

 

or Fuse

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(amp)

 

 

RLBF80C57/72D12

.50GPH-80oA

70,000

57,000

83

2.0-3.0

6

18 x 19

120/60/1

15

40

250

.65GPH-80oB

90,000

74,000

 

 

 

 

 

 

 

 

 

RLBF80C84/95D16

.65GPH-80oB

105,000

85,000

81

2.5-4.0

6

18 x 19

120/60/1

15

40

250

.75GPH-80oB

119,000

97,000

 

 

 

 

 

 

 

 

 

RLBF80C112/125D20

.85GPH-80oB

140,000

113,000

81

3.0-5.0

6

19 x 21

120/60/1

15

40

285

1.00GPH-80oB

154,000

125,000

RLBR80C57/72D12

.50GPH-80oA

70,000

57,000

83

1.5-3.0

6

18 x 19

120/60/1

15

40

250

.65GPH-80oB

90,000

74,000

 

 

 

 

 

 

 

 

 

RLBR80C84/95D16

.65GPH-80oB

105,000

85,000

81

2.5-4.0

6

18 x 19

120/60/1

15

40

255

.75GPH-80oB

119,000

97,000

 

 

 

 

 

 

 

 

 

RLBR80C112/125D20

.85GPH-80oB

140,000

113,000

81

3.0-5.0

6

19 x 21

120/60/1

15

40

290

1.00GPH-80oB

154,000

125,000

RLBR80C140/168D20

1.10GPH-80oB

175,000

140,000

80

3.5-5.0

6

20 1/8 x 22 7/16

120/60/1

15

40

295

1.25GPH-80oB

210,000

168,000

 

 

 

 

 

 

 

 

 

RLBF80C57B08

.50GPH-80oA

70,000

57,000

82

2.0-2.51

6

18 x 19

120/60/1

15

122

255

RLBF80C84/95B10

.65GPH-80oB

105,000

85,000

81

2.0-3.01

6

18 x 19

120/60/1

15

122

255

.75GPH-80oB

119,000

96,000

81

 

 

 

 

 

 

 

 

RLBF80C112/125B16

.85GPH-80oB

140,000

113,000

81

3.0-5.01

6

19 x 21

120/60/1

20

122

290

1.00GPH-80oB

154,000

125,000

81

 

 

 

 

 

 

 

 

RLBR80C57B08

.50GPH-80oA

70,000

57,000

82

2.0-2.51

6

18 x 19

120/60/1

15

122

260

RLBR80C84/95B10

.65GPH-80oB

105,000

85,000

81

2.0-3.01

6

18 x 19

120/60/1

15

122

260

.75GPH-80oB

119,000

97,000

81

 

 

 

 

 

 

 

 

RLBR80C112/125B16

.85GPH-80oB

140,000

113,000

81

3.0-5.01

6

19 x 21

120/60/1

20

122

295

1.00GPH-80oB

154,000

125,000

81

 

 

 

 

 

 

 

 

RLBR80C196B24

1.50GPH-80oB

245,000

196,000

80

5.0-6.0

8

24 5/8 x 24 3/8

120/60/1

20

122

390

1See Table for Alternate Motors for Cooling Combinations

212 Volt heating only. Additional transformer required for cooling applications.

NOTE: All models are rated at 140 psi pump pressure except the RLBF/R 57/72 which is rated at 100 psi.