Ducane (HVAC) RLBF/R80C Blower Performance - Direct Drive, Motor, Temp, Size, Speed, 2,221, 1,501

Models: RLBF/R80C

1 6
Download 6 pages 52.16 Kb
Page 3
Image 3

Blower Performance - Direct Drive

 

Motor

Blower

Temp.

Blower

 

CFM @ ext. static pressure - in. W.C.

 

 

Model

Size

Rise

 

 

 

 

 

 

 

 

 

Size

Speed

.20

.30

.40

.50

.60

.70

 

.80

.90

 

(hp)

(oF)

 

 

 

 

 

 

 

 

 

High

1,400

1,350

1,307

1,250

1,187

1,105

 

1,027

914

RLBF80C57/72D12

1/3

10 x 8

45 - 75

Med High

1,136

1,130

1,103

1,075

1,027

967

 

895

765

Med

930

917

903

867

843

798

 

728

632

 

 

 

 

 

 

 

 

 

Low

783

773

753

732

706

663

 

604

518

 

 

 

 

High

1,760

1,670

1,599

1,550

1,410

1,315

 

1,170

998

RLBF80C84/95D16

1/2

10 x 9

45 - 75

Med High

1,603

1,415

1,459

1,394

1,307

1,190

 

1,080

936

Med

1,373

1345

1,300

1,259

1,188

1,075

 

975

832

 

 

 

 

 

 

 

 

 

Low

1,162

1,150

1,130

1,105

1,033

955

 

853

650

 

 

 

 

High

2,160

2,080

2,010

1,969

1,850

1,735

 

1,627

1,510

RLBF80C112/125D20

3/4

12 x 10

45 - 75

Med High

1,850

1,810

1,744

1,670

1,580

1,510

 

1,403

1,305

Med

1,650

1,600

1,580

1,490

1,430

1,370

 

1,310

1,236

 

 

 

 

 

 

 

 

 

Low

1,480*

1,470*

1,445*

1,380*

1,330*

1,276*

 

1,197*

1,090*

 

 

 

 

High

1,400

1,350

1,307

1,250

1,187

1,105

 

1,027

914

RLBR80C57/72D12

1/3

10 x 8

45 - 75

Med High

1,136

1,130

1,103

1,075

1,027

967

 

895

765

Med

930

917

903

867

843

798

 

728

632

 

 

 

 

 

 

 

 

 

Low

783

773

753

732

706

663

 

604

518

 

 

 

 

High

1,760

1,670

1,599

1,550

1,410

1,315

 

1,170

998

RLBR80C84/95D16

1/2

10 x 9

45 - 75

Med High

1,603

1,415

1,459

1,394

1,307

1,190

 

1,080

936

Med

1,373

1345

1,300

1,259

1,188

1,075

 

975

832

 

 

 

 

 

 

 

 

 

Low

1,162

1,150

1,130

1,105

1,033

955

 

853

650

 

 

 

 

High

2,221

2,124

2,029

1,980

1,835

1,730

 

1,575

1,514

RLBR80C112/125D20

3/4

12 x 10

45 - 75

Med High

1,815

1,755

1,704

1,625

1,549

1,454

 

1,350

1,250

Med

1,564

1,525

1,501

1,435

1,369

1,279

 

1,206

1,114

 

 

 

 

 

 

 

 

 

Low

1,360*

1,355*

1,310*

1,260*

1,205*

1,150*

 

1,087*

998*

 

 

 

 

High

2,245

2,138

2,034

1,985

1,833

1,750

 

1,690

1,550

RLBR80C140/168D20

3/4

12 x 10

45 - 75

Med High

1,835

1,780

1,729

1,670

1,609

1,523

 

1,415

1,318

Med

1,620

1,590

1,540

1,490

1,435

1,335

 

1,269

1,188

 

 

 

 

 

 

 

 

 

Low

1,460*

1,435*

1,400*

1,320*

1,280*

1,200*

 

1,132*

1,050*

*Not recommended for heating. Temperature rise may be outside acceptable range.

Page 3
Image 3
Ducane (HVAC) RLBF/R80C warranty Blower Performance - Direct Drive, Motor, Temp, Size, Speed, 2,221, 1,501, Model