Phenomena that may be easy to be mistaken for machine defects

WARNING ►Never use the projector if abnormal operations such as smoke, strange odor, excessive sound, damaged casing or elements or cables, penetration of liquids or foreign matter, etc. should occur. In such cases, immediately turn off the power switch and then disconnect the power plug from the power outlet. After making sure that the smoke or odor has stopped, contact your dealer or service company.

1. Before requesting repair, please check in accordance with the following chart. This

operation sometimes resolves your problem. If the situation cannot be corrected,

2. The projector’s microprocessor may need to be

reset. Please push the Restart switch by using a cocktail stick or similar and the projector will restart.

3. Some setting may be wrong. Please use the FACTORY RESET function of the SERVICE item in the OPTION menu (39) to reset all settings to factory default.

Then, if the problem is not removed after the remedy, please contact your dealer or service company.

Phenomenon

Cases not involving a machine defect

Reference

page

 

 

 

 

 

 

The electrical power cord is not plugged in.

14

 

Correctly connect the power cord.

 

 

 

The power switch is not set to the on position.

17

 

Set the power switch to [ ] (On).

 

 

 

The main power source has been interrupted during

 

Power does not

operation such as by a power outage (blackout), etc.

17

Please turn the power off, and allow the projector to cool

come on.

down at least 2 minutes. After the projector has sufficiently

 

 

cooled down, please turn the power on again.

 

 

Either there is no lamp and/or lamp cover, or either

 

 

of these has not been properly fixed.

 

 

Please turn the power off, and allow the projector to cool down

40, 41

 

at least 45 minutes. After the projector has sufficiently cooled

 

 

 

down, please make confirmation of the attachment state of the

 

 

lamp and lamp cover, and then turn the power on again.

 

 

The signal cables are not correctly connected.

12, 13

 

Correctly connect the connection cables.

 

 

 

Signal source does not correctly work.

Neither sounds

Correctly set up the signal source device by referring to the

manual of the source device.

 

nor pictures are

 

The input changeover settings are mismatched.

18

outputted.

Select the input signal, and correct the settings.

 

 

 

The RGB IN2 port is assigned to an RGB out while

12

 

an RGB input signal is inputted to the port.

 

Push the RGB IN OUT switch to switch the function of the port.

 

50

Page 52
Image 52
Dukane 8755D-RJ, 8065 user manual Electrical power cord is not plugged, Power switch is not set to the on position

8755D-RJ, 8065, 8755D specifications

The Dukane 8755D, 8065, and 8755D-RJ are innovative ultrasonic welding machines designed to accommodate a wide range of industrial applications. Renowned for their advanced technology and reliable performance, these models exemplify the prowess of Dukane in the field of ultrasonic joining solutions.

The Dukane 8755D offers exceptional versatility and precision, making it ideal for applications in various sectors, including automotive, medical devices, and consumer electronics. One of its standout features is the use of a digital frequency generator, which ensures exact frequency control and stability. This technology allows for efficient energy transfer during the welding process, resulting in stronger and cleaner welds. Additionally, the machine includes adjustable amplitude settings, enabling operators to fine-tune the welding parameters according to specific material requirements.

The Dukane 8065 model complements the 8755D with its powerful ultrasonic capabilities and user-friendly interface. It is equipped with advanced software that facilitates real-time monitoring and data collection, allowing for comprehensive quality control throughout the welding process. The 8065 also features an ergonomic design, improving operator comfort and efficiency during prolonged use, which is essential in high-volume production settings.

The 8755D-RJ model stands out for its integration of enhanced communication features, suited for applications where connectivity and automation are paramount. Its RJ interface allows seamless integration with other machinery and automation systems, making it an excellent choice for smart manufacturing environments. This model also includes robust safety features to protect operators and equipment, ensuring a safe working environment.

All three machines leverage Dukane's proprietary ultrasonic technology, which provides consistent weld quality while minimizing energy consumption. Their compact design allows for easy integration into existing production lines without significant modifications. The ability to process a wide variety of materials, including thermoplastics and metals, further enhances the adaptability of these ultrasonic welders.

In summary, the Dukane 8755D, 8065, and 8755D-RJ represent cutting-edge ultrasonic welding solutions tailored for diverse industrial applications. With their advanced features, innovative technologies, and user-friendly designs, these models ensure high-quality welds and enhanced production efficiency, making them invaluable assets in any manufacturing process.