RS-232C Communication (continued)

Requesting projector status (Get command)

(1)Send the request code Header + Command data (‘02H’+‘00H’+ type (2 bytes)+ ‘00H’ +‘00H’) from the computer to the projector.

(2)The projector returns the response code ‘1DH’+ data (2 bytes) to the computer.

Changing the projector settings (Set command)

(1)Send the setting code Header + Command data (‘01H’+‘00H’+ type (2 bytes) + setting code (2 bytes)) from the computer to the projector.

(2)The projector changes the setting based on the above setting code.

(3)The projector returns the response code ‘06H’ to the computer.

Using the projector default settings (Reset Command)

(1)The computer sends the default setting code Header + Command data (‘06H’+ ‘00H’ + type (2 bytes) +‘00H’+‘00H’) to the projector.

(2)The projector changes the specified setting to the default value.

(3)The projector returns the response code ‘06H’ to the computer.

Increasing the projector setting value (Increment command)

(1)The computer sends the increment code Header + Command data (‘04H’+ ‘00H’+ type (2 bytes) +‘00H’+‘00H’) to the projector.

(2)The projector in creases the setting value on the above setting code.

(3)The projector returns the response code ‘06H’ to the computer.

Decreasing the projector setting value (Decrement command)

(1)The computer sends the decrement code Header + Command data (‘05H’+ ‘00H’+ type (2 bytes) +‘00H’ + ‘00H’) to the projector.

(2)The projector decreases the setting value on the above setting code.

(3)The projector returns the response code ‘06H’ to the computer.

When the projector cannot understand the received command

When the projector cannot understand the received command, the error code ‘15H’ is sent back to the computer.

Sometimes the projector cannot properly receive the command. In such a case, the command is not executed and the error code ‘15H’ is sent back to the computer. If this error code is returned, send the same command again.

When the projector cannot execute the received command.

When the projector cannot execute the received command, the error code ‘1cH’

+‘xxxxH’ is sent back to the computer. When the data length is greater than indicated by the data length code, the projector ignore the excess data code. Conversely when the data length is shorter than indicated by the data length code, an error code will be returned to the computer.

NOTE • Operation cannot be guaranteed when the projector receives an undefined command or data.

Provide an interval of at least 40ms between the response code and any other code.

The projector outputs test data when the power supply is switched ON, and when the lamp is lit. Ignore this data.

Commands are not accepted during warm-up.

103

Page 105
Image 105
Dukane 8755D-RJ, 8065 user manual Requesting projector status Get command, Changing the projector settings Set command

8755D-RJ, 8065, 8755D specifications

The Dukane 8755D, 8065, and 8755D-RJ are innovative ultrasonic welding machines designed to accommodate a wide range of industrial applications. Renowned for their advanced technology and reliable performance, these models exemplify the prowess of Dukane in the field of ultrasonic joining solutions.

The Dukane 8755D offers exceptional versatility and precision, making it ideal for applications in various sectors, including automotive, medical devices, and consumer electronics. One of its standout features is the use of a digital frequency generator, which ensures exact frequency control and stability. This technology allows for efficient energy transfer during the welding process, resulting in stronger and cleaner welds. Additionally, the machine includes adjustable amplitude settings, enabling operators to fine-tune the welding parameters according to specific material requirements.

The Dukane 8065 model complements the 8755D with its powerful ultrasonic capabilities and user-friendly interface. It is equipped with advanced software that facilitates real-time monitoring and data collection, allowing for comprehensive quality control throughout the welding process. The 8065 also features an ergonomic design, improving operator comfort and efficiency during prolonged use, which is essential in high-volume production settings.

The 8755D-RJ model stands out for its integration of enhanced communication features, suited for applications where connectivity and automation are paramount. Its RJ interface allows seamless integration with other machinery and automation systems, making it an excellent choice for smart manufacturing environments. This model also includes robust safety features to protect operators and equipment, ensuring a safe working environment.

All three machines leverage Dukane's proprietary ultrasonic technology, which provides consistent weld quality while minimizing energy consumption. Their compact design allows for easy integration into existing production lines without significant modifications. The ability to process a wide variety of materials, including thermoplastics and metals, further enhances the adaptability of these ultrasonic welders.

In summary, the Dukane 8755D, 8065, and 8755D-RJ represent cutting-edge ultrasonic welding solutions tailored for diverse industrial applications. With their advanced features, innovative technologies, and user-friendly designs, these models ensure high-quality welds and enhanced production efficiency, making them invaluable assets in any manufacturing process.