Dynacord 315 owner manual Important Safety Instructions

Models: 315

1 24
Download 24 pages 19.5 Kb
Page 11
Image 11

IMPORTANT SAFETY INSTRUCTIONS

The lightning flash with arrowhead symbol, within an equilateral triangle is intended to alert the user to the presence of uninsulated ”dangerous voltage” within the product’s enclosure that may be of sufficent magnitude to constitute a risk of electric shock to per- sons.

The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintance (servicing) instructions in the literature accompanying the appliance.

1.Read these instructions.

2.Keep these instructions.

3.Heed all warnings.

4.Follow all instructions.

5.Do not use this apparatus near water.

6.Clean only with a dry cloth.

7.Do not cover any ventilation openings. Install in accordance with the manufacturer’s instructions.

8.Do not install near heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.

9.Do not defeat the safety purpose of the polarized or the grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your out- let, consult an electrician for replacement of the obsolete outlet.

10.Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.

11.Only use attachments/accessories specified by the manufacturer.

12.Use only with the cart, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.

13.Unplug this apparatus during lightning storms or when unused for a long period of time.

14.Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power- supply cord or plug is damaged, liquid has been spilled or orbjects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.

15.Do not expose this equipment to dripping or splashing and ensure that no objects filled with liquids, such as vases, are placed on the equipment.

16.To completely disconnect this equipment from the AC Mains, disconnect the power supply cord plug from the AC receptacle.

17.The mains plug of the power supply cord shall remain readily operable.

18.No naked flame sources, such as lighted candles, should be placed on the apparatus.

19.The product should be connected to a mains socket outlet with a protective earthing connection.

IMPORTANT SERVICE INSTRUCTIONS

CAUTION: These servicing instructions are for use by qualified personnel only. To reduce the risk of electric shock, do not perform any servicing other than that contained in the Operating Instructions unless you are qualified to do so. Refer all servicing to qualified service personnel.

1.Security regulations as stated in the EN 60065 (VDE 0860 / IEC 65) and the CSA E65 - 94 have to be obeyed when servicing the appliance.

2.Use of a mains separator transformer is mandatory during maintenance while the appliance is opened, needs to be operated and is connected to the mains.

3.Switch off the power before retrofitting any extensions, changing the mains voltage or the output voltage.

4.The minimum distance between parts carrying mains voltage and any accessible metal piece (metal enclosure), respectively between the mains poles has to be 3 mm and needs to be minded at all times. The minimum distance between parts carrying mains voltage and any switches or breakers that are not con- nected to the mains (secondary parts) has to be 6 mm and needs to be minded at all times.

5.Replacing special components that are marked in the circuit diagram using the security symbol (Note) is only permissible when using original parts.

6.Altering the circuitry without prior consent or advice is not legitimate.

7.Any work security regulations that are applicable at the locations where the appliance is being serviced have to be strictly obeyed. This applies also to any regulations about the work place itself.

8.All instructions concerning the handling of MOS-circuits have to be observed.

NOTE:

SAFETY COMPONENT (MUST BE REPLACED BY ORIGINAL PART)

WEEE RECYCLING/DISPOSAL INSTRUCTIONS

The Wheelie Bin symbol found on the product or in the manual indicates that this product must not be disposed of with other waste. It is in our category the manufacturer’s responsibility to properly dispose of their waste electrical and electronic equipment (WEEE) at the end of its life. Due to the differences in each EU country’s management of WEEE, please contact your local distributor. We are committed to facilitate our own electronic-waste-management-system, for the free of charge return of all EVI Audio GmbH products: Telex, DYNACORD, Electro-Voice and RTS. Arrangements are made with the dealer where you purchased the equipment from, for the returning of all unusable equipment at no cost, to the factory in Straubing, for environmental protective disposal.

Due to line current harmonics, we recommend that you contact your supply authority before connection.

Page 11
Image 11
Dynacord 315 owner manual Important Safety Instructions

315 specifications

The Dynacord 315 is a professional-grade loudspeaker designed to deliver high-quality sound for various applications, including live performances, installations, and events. Over the years, Dynacord has established itself as a leader in audio technology, and the 315 model is a testament to their commitment to innovation, performance, and reliability.

One of the main features of the Dynacord 315 is its powerful performance capabilities. With a maximum SPL (Sound Pressure Level) of 134 dB, this speaker is capable of filling large venues with clear, impactful sound. The 315 is equipped with a 15-inch heavy-duty woofer that provides deep, rich bass, while a high-frequency horn ensures that higher frequencies are reproduced with precision and clarity. This makes it an ideal choice for music genres that demand a full range of sound reproduction.

The Dynacord 315 also incorporates advanced technologies that enhance its performance and versatility. One such feature is the integrated DSP (Digital Signal Processing) that optimizes the speaker’s sound output based on the specific acoustic environment. This means that whether you’re using it in a small club or an outdoor festival, the 315 can adjust to deliver the best possible sound quality.

Another significant characteristic of the 315 is its rugged build. Built to withstand the rigors of touring and live events, the speaker features a durable cabinet made from high-quality materials. The design includes protective corner reinforcements and a rugged grille that helps prevent damage during transport and handling. Additionally, the lightweight construction allows for easy setup and transportation, making it a practical solution for sound engineers and performers.

Connectivity features also set the Dynacord 315 apart. It typically includes multiple input options, allowing users to connect various audio sources, from microphones to instruments and playback devices. This flexibility makes it a suitable choice for a wide range of applications, from small gigs to large-scale productions.

In summary, the Dynacord 315 stands out in the professional audio market with its powerful sound performance, advanced DSP technology, rugged construction, and versatile connectivity options. Its design reflects Dynacord's commitment to quality and innovation, making it an excellent choice for audio professionals seeking reliability and exceptional sound reproduction in challenging environments. Whether in the studio or on the stage, the Dynacord 315 promises to deliver the high standards expected from a leading audio brand.