IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

The lightning flash with arrowhead symbol, within an equilateral triangle is intended to alert the user to the presence of uninsulated „dangerous voltage“ within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.

The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintance (servicing) instructions in the

literature accompanying the appliance.

Read these instructions. Keep these instructions. Heed all warnings.

Follow all instructions.

Do not use this apparatus near water. Clean only with a dry cloth.

Do not block any ventilation openings. Install in accordance with the manufactures instructions. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.

Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrican for replacement of the obsolete outlet.

Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.

Only use attachments/accessories specified by the manufacturer.

Unplug this apparatus during lightning storms or when unused for long periods of time.

Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped. Do not expose this equipment to dripping or splashing and ensure that no objects filled with liquids, such as vases, are placed on the equipment.

To completely disconnect this equipment from the AC Mains, disconnect the power supply cord plug from the AC receptacle.

The mains plug of the power supply cord shall remain readily operable.

Management of WEEE (waste electrical and electronic equipment) (applicable in Member States of the European Union and other European countries with individual national policies on the management of WEEE) The symbol on the product or on its packaging indicates that this product may not be treated as regular household waste, but has to be disposed through returning it at a Telex dealer.

 

IMPORTANT SERVICE INSTRUCTIONS

CAUTION:

These servicing instructions are for use by qualified personnel only. To reduce the risk of

 

electric shock, do not perform any servicing other than that ontained in the Operating

 

Instructions unless you are qualified to do so. Refer all servicing to qualified service personnel.

1.Security regulations as stated in the EN 60065 (VDE 0860 / IEC 65) and the CSA E65 - 94 have to be obeyed when servicing the appliance.

2.Use of a mains separator transformer is mandatory during maintenance while the appliance is opened, needs to be operated and is connected to the mains.

3.Switch off the power before retrofitting any extensions, changing the mains voltage or the output voltage.

4.The minimum distance between parts carrying mains voltage and any accessible metal piece (metal enclosure), respectively between the mains poles has to be 3 mm and needs to be maintained at all times. The minimum distance between parts carrying mains voltage and any switches or breakers that are not connected to the mains (secondary parts) has to be 6 mm and needs to be maintained at all times.

5.Replacing special components that are marked in the circuit diagram using the security symbol (Note) is only permissible when using original parts.

6.Altering the circuitry without prior consent or advice from the manufacturer is not legitimate.

7.Any work security regulations that are applicable at the location where the appliance is being serviced have to be strictly obeyed. This applies also to any regulations about the work place itself.

8.All instructions concerning the handling of MOS - circuits have to be observed.

NOTE: IMPORTANT SERVICE INSTRUCTIONS SAFETY COMPONENT ( MUST BE REPLACED BY ORIGINAL PART )

16

Page 16
Image 16
Dynacord DPA 4245, DPA 4260 owner manual Important Safety Instructions, Important Service Instructions

DPA 4260, DPA 4245 specifications

Dynacord, a renowned name in professional audio equipment, has established a reputation for delivering high-performance amplifiers that meet the rigorous demands of live sound and installation applications. The DPA 4260 and DPA 4245 models stand out in their lineup, featuring advanced technologies and robust characteristics that set them apart in the competitive audio landscape.

The Dynacord DPA 4260 is a powerful four-channel amplifier that offers an impressive output of up to 2,600 watts, designed to drive a wide range of speakers effortlessly. One of its main features is the implementation of a sophisticated DSP (Digital Signal Processing) technology, which provides comprehensive control over audio parameters such as EQ, crossover, delay, and limiter settings. This allows users to optimize the sound output for various environments, ensuring clarity and fidelity in the audio performance.

In addition to DSP, the DPA 4260 is equipped with an advanced Power Factor Correction (PFC) system. This technology not only enhances the amplifier's efficiency but also ensures stable performance even under varying load conditions. The amplifier's robust build quality and efficient heat dissipation design make it suitable for extended operation in demanding venues.

On the other hand, the Dynacord DPA 4245 is another impressive model offering a slightly lower output of 1,400 watts but packed with its unique set of features. Like the DPA 4260, it benefits from the same DSP capabilities, allowing for detailed sound manipulation and tuning. This is particularly useful for sound engineers looking for precision in their audio setups.

The DPA 4245 also showcases versatility in its operation, featuring a selection of operating modes to accommodate different configurations, including bridge mode for driving larger loads. Its lightweight design makes it easy to transport and install without compromising on power or performance.

Both models come with comprehensive connectivity options, ensuring compatibility with various audio systems and setups, facilitating seamless integration into existing infrastructures. The front panel allows for easy monitoring, featuring LED indicators that display operational status and signal integrity.

In conclusion, Dynacord's DPA 4260 and DPA 4245 amplifiers exemplify cutting-edge technology and robust construction in the world of professional audio. With their powerful outputs, advanced DSP capabilities, and flexible configurations, these amplifiers are designed to meet the demands of professionals seeking reliable and high-quality audio solutions in live sound reinforcement and installation applications. Whether for touring, installations, or events, these amplifiers ensure a professional sound experience.