Mains Operation And Leakage Power
The mains power consumption as well as the leakage power is stated for driving the power amplifier at different levels. All the values were measured at nominal load via the 100 V output with two channels driven. The shown values differ only slightly when the appliance is operated at different nominal output voltages or in the Direct Out mode.
mains operation at the 100 | Umains[V] | Imains [A] | Pmains | Pmains [W] | Pout [W] | Pv [W] | BTU/hr |
V output |
|
| [VA] |
|
|
|
|
|
|
|
|
|
|
| |
DPA 4245 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
idling | 230V | 0,34 | 78 | 47 | — | 47 | 160 |
normal operation | 230V | 2,76 | 635 | 490 | 70 | 420 | 1430 |
alarm | 230V | 5,54 | 1274 | 1040 | 352 | 688 | 2347 |
nominal conditions | 230V | 7,45 | 1714 | 1420 | 700 | 720 | 2456 |
DPA 4260 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
idling | 230V | 0,57 | 131 | 80 | — | 80 | 273 |
normal | 230V | 3,66 | 842 | 655 | 101 | 554 | 1890 |
alarm | 230V | 7,34 | 1688 | 1370 | 506 | 864 | 2948 |
nominal conditions | 230V | 9,86 | 2268 | 1900 | 1000 | 900 | 3070 |
initial current inrush for both models: < 38 A
Pmains[VA] = apparent power Umains*Imains, Pmains[W] = active power, Pout[W] = output power, Pv[W] = leakage power, 1BTU = 1055.06 W/s
Fuses
location | pos. | utilization | value | dimensions | standard |
rear panel DPA 4245 | mains fuse 230V~ AC | T8A 250V | 5 x 20 mm | IEC 127 | |
rear panel DPA 4245 | mains fuse 230V~ AC | T10A 250V | 5 x 20 mm | IEC 127 | |
print 84171/1 | F1 | power supply | T1A 250V | 5 x 20 mm | IEC 127 |
|
|
|
|
|
|
print 84171/1 | F2 | power supply | T1A 250V | 5 x 20 mm | IEC 127 |
Extension Kits For The DPA 4245 And The DPA 4260:
NRS 90208 balanced input (input transformer for a single channel)
NRS 90235 1 pair of