If a Common or 24vac terminal cannot be located, it will be necessary to install a separate transformer. If a
5)If necessary, route the power cord through the furnace/air handler cabinet to the filter rack area. If an existing access hole is not available, drill a 7/16” hole. A grommet is provided to fit a 7/16" hole (fig 2). The cord should be run so that it is not crimped or abraded and should have enough slack to allow the air cleaner to be easily removed for routine maintenance. Position the power cord slack to keep it away from the furnace/air handler blower and other moving parts.
Figure 2
6)Install the air cleaner into the filter rack or return air grille.
7)Plug the power cord into the air cleaner once it is securely in place (fig 3).
8)Close the filter access door or grille.
9)Turn on the power to the furnace/air handler. The power indicator light on the air cleaner should illuminate.
10)Turn the thermostat fan switch to the “ON” position.
NOTE: For best air cleaning efficiency and optimum comfort, the furnace/air handler blower should be run continuously with the fan switch in the “ON” position rather than in the “AUTO” position.
Figure 3
11)If arcing occurs within the air cleaner, see the instructions in section III for replacing the air cleaner Media Pad.
12)Affix the caution sticker and Media Pad Replacement Record in a prominent location near the air cleaner.
Section II. Optional Plug-In Transformer
As an optional accessory, a
WARNING: DO NOT SUBSTITUTE OTHER
Section III. Maintenance and Media Pad Replacement
Replacement Media Pads are available from your heating and air conditioning contractor or by ordering online at www.DynamicAQS.com.
WARNING: WHENEVER INSTALLING OR REMOVING THE AIR CLEANER, THE POWER TO THE FURNACE/AIR HANDLER MUST BE TURNED OFF. CARE SHOULD BE TAKEN NOT TO LET THE JACK TOUCH ANY GROUNDED OR METAL SURFACES. ALTHOUGH THE JACK IS SHIELDED, IT IS POSSIBLE FOR THE CENTRAL POWER INSERT TO CONTACT GROUND WHICH COULD RESULT IN DAMAGE TO THE TRANSFORMER OR ELECTRONICS.
2