BEFORE USING THIS AIR TOOL

BEFORE USING THIS AIR TOOL

To ensure long life be sure to oil the tool daily. Pour 4 drops of Eagle air tool (SEA 20 non detergent) oil into the air inlet, and then run the tool for a few seconds to clean.

If tool is an impact wrench fitted with a “Zirc” grease fitting:

The hammer mechanism of this tool also needs to be greased from time to time (depending on usage). The tool is equipped with grease fitting for this purpose; use this connection to re-grease the tool using Eagle impact wrench grease.

PLEASE USE EAGLE SEA 20 NON DETERGENT OIL

OPERATING INSTRUCTIONS

Do not put additional pressure on the tool, this will only reduce efficiency and shorten the tool’s life. We recommend the air pressure of this grinder at 90 PSI.

When using the grinder be careful not to exert excessive force. Too much force could be hazardous if it caused the cutting tool spindle to bend or break.

The burning of the work piece or excessive speed reduction indicates too much force being applied. Changing to a cutting tool may be better for the desired rate of speed and stock removal.

Avoid hazardous conditions by making sure there is sufficient gripping force on the spindle of cutting tool by placing the spindle 7/16” or more inside the collet.

Lubricate the motor with a good grade of air tool oil. Grit or gum deposit in the tool may cut power and may be corrected by cleaning the air strainer and flushing out the tool with gum solvent oil.

TROUBLESHOOTING

SYMPTOMS

CAUSE

REMEDY

Air tool does not

Lack of lubrication.

Lubricate as per instructions.

run or runs slow.

 

 

 

 

 

 

Dirt in tool.

Clean with mixture of 50/50 tool

 

 

 

oil/solvent. Lubricate after cleaning.

 

 

 

 

Insufficient air pressure.

Check regulator and air supply for

 

 

 

leaks. Check compressor to make

 

 

sure it operates at correct pressure.

 

 

Make sure air hose is properly sized

 

 

and that multiple hoses are not

 

 

connected to same outlet. Check air

 

 

hose for leaks and repair.

 

Rotor blades worn or motor

Replace blades, inspect clean or

 

 

bearing worn or dirty.

replace bearing.

IMPACT WRENCH

See causes (above).

See remedies (above).

does not impact or

 

 

impacts slowly.

 

 

 

Broken or worn impact

Inspect and repair as required.

 

 

mechanism.

 

Wear hearing protection.

Wear eye protection.

Wear respiratory protection.

Read the instruction manual

Page 5
Image 5
Eagle Electronics EGA530 Before Using This Air Tool, Operating Instructions, Troubleshooting, Symptoms, Cause, Remedy