Power Edger Attachment 11

Operator's Manual

5.Clean all loose debris from gear box.

6.Remove plug (G) and check level of grease. Grease should fill gear case to bottom of grease plug hole.

G

7.Add grease if necessary using manual grease gun or squeeze-type tube. Do not use high pressure grease gun. DO NOT over-fill.

8.Install inner blade adapter (B) onto PTO shaft (C).

9.Install and center new blade (F) onto inner adapter (B).

10.Install outer adapter (E) and nut (D). Tighten nut (D) firmly, counterclockwise (CCW).

IMPORTANT

Never reuse old split pin.

11. Install new split pin (A) to secure nut.

Drive Shaft (Lower)

IMPORTANT

Lower and upper drive shaft must be lubricated with high temperature automotive grease every 25 hours of operation, otherwise drive shaft assembly overheating and failure can result.

1. Loosen two (2) screws (A) and remove center locating screw (B).

A

 

Pull gear box and shield from drive shaft housing.

 

2.Pull flexible cable (C) from the drive shaft housing, wipe clean and re-coat with a thin coating [15 ml (1/2 oz.)] of grease.

3. Slide the flexible cable (C) back in the drive housing. DO NOT get

B

dirt on the flex cable.

 

4. Install the gear housing and shield assembly.