ASSEMBLY

ES-250

ASSEMBLY

 

 

Remove Blower Pipes

1.Insert screwdriver (F) into hole located near lock symbol (G) to release pipe lock.

Screwdriver tip may stick out opposite side of locking hole.

2.Pull pipe out of fan case.

3.Remove screwdriver.

Vacuum/Shredding Application

Install Vacuum Tube

1.Turn knob (I) counter clockwise until hinged housing cover is free to open for vacuum tube installation.

2.Opening housing cover, slide recess (J) on vacuum tube into locking rib (K), and turn the vacuum tube clockwise so that it is locked.

Note: Engine will not start/operate unless safety interlock switch (K) is activated by the vacuum tube.

Install Bag

1. Stand unit upright on blower base.