| HEDGE CLIPPER | 19 | |||||
|
|
|
|
|
| OPERATOR'S MANUAL | |||||||
| MAINTENANCE INTERVALS |
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Daily | 3 | 6 |
|
|
|
|
|
|
|
| Maintenance |
|
| or |
| Yearly |
| |||
|
| Component/System |
| Before | Every | Months | Months |
|
| ||||
|
|
| Every |
| or 600 |
| |||||||
|
|
| Procedure | Use | Refuel | or 100 | or 300 |
|
| ||||
|
|
|
| 4 |
| Hours |
| ||||||
|
|
|
|
|
| Hours | Hours |
|
| ||||
|
|
|
|
|
|
| Hours |
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Air Filter |
| Inspect/Replace | I / C |
| I / C | R * |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Fuel Strainer |
| Inspect/Replace |
|
|
| I |
|
|
| R |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Fuel Line |
| Inspect/Replace | I |
|
| I * |
|
|
| R |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
| Carburetor |
| Inspect/Replace |
|
|
|
| C |
| R(1) |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Choke System |
| Inspect/Replace |
| I |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Cooling System |
| Inspect/Clean | I / C |
| I / C |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Muffler Spark Arrestor |
| Inspect/Clean/Replace |
|
|
| I / C |
|
|
| R |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Gear Housing |
| Grease | I (2) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Recoil Starter |
| Inspect/Clean | I |
|
|
|
|
|
| I * |
|
|
| Rope |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Fuel Leaks |
| Inspect/Repair | I | I |
|
|
|
|
| I * |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Spark Plug |
| Clean |
|
|
| I / C | R * |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
| Ignition System |
| Clean/Replace | No Maintenance required for coil and flywheel |
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Screws/Nuts/Bolts |
| Inspect/Tighten/Replace | I* |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
| I = INSPECT, R = REPLACE, C = CLEAN |
|
|
|
|
|
|
|
|
| ||
|
| IMPORTANT Time intervals shown are maximum. Actual use and your experience will determine the frequency of |
|
|
| ||||||||
|
| required maintenance. |
|
|
|
|
|
|
|
|
|
| |
|
| * All recommendations to replace are based on the finding of damage or wear during inspection. |
|
|
|
|
| ||||||
|
| (1) Replacement will be required for Commercial use after 600 hours. For Consumer use, cleaning every 6 months is |
|
|
| ||||||||
|
| required. |
|
|
|
|
|
|
|
|
|
| |
|
| (2) Apply 1~2 pumps of ECHO | LUBETM every 10 hours. |
|
|
|
|
|
|
|
|
| |
|
| ® |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|