12
1.Stop Switch
Move stop switch button (A) away from the STOP position.
2.Throttle Position Lever
Move throttle position lever (B) midway between idle and full throttle positions.
3.Choke
Move choke (C) to Cold Start ( ) Position.
4.Purge Bulb
Pump purge bulb (D) until fuel is visible and flows freely in the clear fuel tank return line.
IMPORTANT
Recoil starter: Use short pulls - only 1/2 ~ 2/3 of rope for start-
ing. Do not allow the rope to snap back in. Always hold the unit
firmly.
5.Recoil Starter
Place the unit on a flat, clear area. Firmly grasp throttle grip with left hand and rapidly pull recoil starter handle/rope (E) until en- gine fires , or maximum 5 pulls.
6.Choke
Move choke lever (C) to Run ( | ) position if necessary, restart |
engine.
NOTE
If engine does not start after 5 pulls, repeat instructions
7.After engine starts, move throttle position lever to idle position, and allow engine to warm up for 3 minutes before use.
8.After engine warms up, depress throttle trigger or move throttle position lever to increase engine RPM to operating speed.
A
B
C
D
E
C