OPERATION | |
|
|
Move stop switch (A) away from the STOP position.
A
2. | Choke |
|
| |
| Move choke lever (B) to Cold Start Position ( | ). |
| |
3. | Purge Bulb |
| B | |
|
|
|
| |
| Pump purge bulb (C) until fuel is visible and flows freely in the |
| ||
| clear fuel tank return line. Pump bulb an additional 4 or 5 |
| ||
| times. |
|
| |
|
|
|
| C |
|
|
|
| D |
4. | Recoil Starter |
|
| |
|
| |||
| Lay the unit on a flat area and keep movable attachment parts |
| ||
| clear of all obstacles. Firmly grasp throttle handle and throttle |
| ||
| trigger lockout with left hand and fully depress throttle trigger |
| ||
| to wide open position. Rapidly pull recoil starter handle/rope |
| ||
| (D) until engine fires (or maximum five [5] pulls). |
|
| |
5. | Choke |
|
| |
| After engine fires (or 5 pulls), move choke (B) to the Run | D | ||
| ( | ) (open) position. Firmly grasp throttle handle and throttle | ||
|
| |||
| trigger lockout with left hand and fully depress throttle trigger |
| ||
| to wide open position. Pull starter handle/rope until engine |
| ||
| starts and runs. Release throttle trigger and allow unit to warm up at idle for several minutes. |
Note: If engine does not start with choke in “Run” position after 5 pulls, repeat instructions 2 - 5.
6.Throttle Trigger
After engine
20 | X7502026004 |
© 9/2014 ECHO Inc.