Attach the drain hose clamp to the

 

back panel of the air conditioner

near the drain port with the screw.

Attach one end of the drain hose

3 to the drain port with the clip provided.

Insert the rubber plug into the

4 other end of the drain hose and secure clip provided.

Draining the Unit

When the portable air conditioner is in cooling mode, or dehumidify mode, it will remove moisture from the air. The condensed water from the air will be collected in an internal reservoir and will be evaporated and exhausted out of the exhaust hose. However, in very humid conditions, the internal reservoir may fill completely. This causes the air conditioner to turn off to avoid overflowing the internal reservoir. When water tank is full a buzzer will sound eight times and on the LED window will display error code “H8”.

Direct drainage

1.Remove the rubber drain plug from the drain port.

2.Connect a drain hose to the drain port.

The portable air conditioner will now drain through the drain hose. Please note that this unit has no drain pump; all water will drain with gravity only, i.e., only “downhill.”

9

Page 12
Image 12
EdgeStar AP10002BL owner manual Draining the Unit, Direct drainage