Manual drainage

Manual drainage

When the portable air conditioner is in cooling or dry mode, it will dehumidify the air. The water dehumidified from the air will be collected in an internal reservoir. This water will be used to help cool the compressor and it will be evaporated and exhausted out the exhaust hose. This unit is designed to exhaust most or all condensate water collected out of the air, but in very humid conditions, the internal reservoir may fill completely. This causes the air conditioner to turn off to avoid overflowing the internal reservoir. The portable air conditioner will begin beeping and the Run light will begin blinking and/or the display will show the E7 code. Drain the unit to return to normal operation.

Drain parts:

1.Drain (there is a rubber plug inside this hole)

2.Drain cap

3.Drain hose

4.Drain tray

Draining with the drain tray

1.Make sure the unit is off.

2.Position the drain tray on the floor beneath the drain.

3.Unscrew the drain cap from the drain. Remove the rubber plug from the drain.

4.When the drain tray is almost full, insert the rubber plug back into the drain and screw the drain cap back onto the drain.