61

System settings

Use

UTILITY mode

(p. 42) to make various system settings for the PC-50.

fig.util*

1

Simultaneously hold the

[MIDI CH]

button and

[PGM CHANGE]

button down.
The display will indicate “UTL,” and the PC-50 enters UTILITY
mode.

fig.sy0

2

Press the

[SYSTEM]

key.
The display will indicate “SY0” and blink.

fig.enter

3

Use the

VALUE encoder

or the

[0]

[9]

keys to specify the System setting that
you want to set, and then press the
[ENTER]
button.
* The setting will be cancelled if you press another button instead of the
[ENTER]
button.
Confirm what’s indicated and use the appropriate method to make the setting.

Set the system settings

Display Mode Key-
board Content of the setting Default Setting
method
F8 CLOCK
ON/OFF 0

Specify whether F8 Clock is to be transmitted. OFF p. 62

F8 CLOCK
DEFAULT
TEMPO
1

If “F8 CLOCK ON/OFF” is ON, specify the default value
of the F8 Clock. After the power is turned on, this tempo
will continue to be output until you move a controller to
which TEMPO is assigned.
120 p. 62

VELOCITY
CURVE 2

When you play the keyboard of the PC-50, note messages
will be transmitted with a velocity value that corresponds
to your playing strength. By setting the VELOCITY
CURVE, you can modify the keyboard’s sensitivity and the
curve that is followed when the velocity value changes.
1-MEDIUM p. 63

KEY
VELOCITY 3

Specify whether the transmitted velocity value will vary
according to the keyboard sensitivity and curve you select-
ed in “VELOCITY CURVE”, or will always be transmitted
at a fixed value.
TOUCH p. 64

MIDI I/F
MODE 4

Specify whether the PC-50 will function as a MIDI interface
using its MIDI connectors. ON p. 65

VALUE
ENCODER 5

Select the parameter that is transmitted by the VALUE en-
coder. VOLUME p. 66

FACTORY
RESET 6

Restore all settings of the PC-50 to their factory-set condi-
tion. - p. 68