Maintenance and Cleaning

Lamp Replacement

When the life of the projection lamp of this projector draws to an end, the LAMP REPLACE indicator emits a yellow light. If this indicator lights yellow, replace the lamp with a new one promptly.

 

 

 

 

 

This indicator is yellow when

 

 

 

 

 

the life of the projection lamp

 

 

 

 

 

 

 

 

WARNING:

 

draws to an end.

 

 

 

TURN OFF THE UV LAMP BEFORE

 

 

 

 

 

OPENING THE LAMP COVER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Top Control

POWER WLAMP REPLACE

ON

INPUT

KEYSTONE

 

 

SELECT

 

 

VOLU

 

+

 

VOLUME

-

 

 

ME

 

 

CAUTION

Allow a projector to cool, for at least 45 minutes before you open the Lamp cover. The inside of the projector can become very hot.

CAUTION

For continued safety, replace with a lamp of the same type. Do not drop a lamp or touch a glass bulb! The glass can shatter and may cause injury.

Follow these steps to replace the lamp.

1

Turn off the projector and disconnect the AC power

 

cord. Allow the projector to cool for at least 45

 

minutes.

2

Remove the screw with a screwdriver, and remove

 

the lamp cover.

3

Remove 2 screws of the lamp with a screwdriver and

 

pull out the lamp by grasping the handle.

4

Replace the lamp with a new one and tighten the 2

 

screws back into position. Make sure that the lamp is

 

set properly. Replace the lamp cover and tighten the

 

screw.

5

Connect the AC power cord to the projector and turn

 

on the projector.

6

Reset the lamp replacement counter.

 

See “Lamp Replacement Counter” on the next page .

Lamp Cover

Screw

Screw

Lamp

Screw Handle

ORDER REPLACEMENT LAMP

Replacement lamp can be ordered through your dealer. When ordering a projection lamp, give the following information to the dealer.

Model No. of your projector : LC-SB22

Replacement Lamp Type No. : POA-LMP90

(Service Parts No. 610 323 0726)

52

Page 52
Image 52
Eiki LC-SB22 owner manual Lamp Replacement, Reset the lamp replacement counter