APPENDIX

LAMP REPLACEMENT

LAMP REPLACE

When the life of the Projection Lamp of this projector draws to an end,

 

TOP CONTROL

the LAMP REPLACE indicator lights yellow. If this indicator lights

 

yellow, replace the projection lamp with a new one promptly.

 

This indicator lights yellow when the life of the projection lamp draws to an end. Replace the Projection Lamp with a new one promptly.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Allow a projector to cool, for at least 45 minutes before

For continued safety, replace with a lamp assembly of

 

you open Lamp Cover. The inside of a projector can

 

the same type.

 

 

become very hot.

 

Do not drop a lamp assembly or touch a glass bulb! The

 

 

 

 

 

glass can shatter and may cause injury.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Follow these steps to replace lamp assembly.

1

Turn off a projector and disconnect AC plug. Allow a projector to

cool for at least 45 minutes.

2

Loosen 2 screws with a screwdriver and open Lamp Cover.

3

Loosen 2 screws with a screwdriver and pull out Lamp Assembly

by grasping Handle.

4

Replace Lamp Assembly with a new one and tighten 2 screws

back. Make sure that Lamp Assembly is set properly. Replace

 

Lamp Cover and tighten 2 screws.

5

Connect AC Power Cord to a projector and turn it on.

6

Reset Lamp Replace Counter (refer to next page “Lamp Replace

Counter” section).

NOTE : Do not reset Lamp Replace Counter when Projection Lamp is not replaced.

 

LAMP COVER

LAMP

HANDLE

ASSEMBLY

 

ORDER REPLACEMENT LAMP

Replacement Lamp can be ordered through your dealer. When ordering a Projection Lamp, give the following information to the dealer.

Model No. of your projector

:

LC-X60

Replacement Lamp Type No.

:

POA-LMP81

 

 

 

(Service Parts No. 610 314 9127)

44