APPENDIX

LAMP REPLACEMENT

When the life of Projection Lamp of this projector draws to an end, LAMP REPLACEMENT indicator lights yellow. When a projected image becomes dark or the color of an image becomes unnatural, replacement of Projection Lamp is required.

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

 

 

 

CAUTION

 

 

 

 

For continued safety, replace with a lamp

 

 

 

Do not drop a lamp assembly or touch a glass

 

 

 

 

assembly of the same type.

 

 

 

bulb! The glass can shatter and may cause

 

 

 

 

Allow a projector to cool for at least 45

 

 

 

injury.

 

 

 

 

minutes before you open Lamp Cover. The

 

 

 

 

 

 

 

 

 

 

 

 

 

inside of a projector can become very hot.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Follow these steps to replace the lamp assembly.

LAMP COVER

1

Turn off the projector and disconnect AC plug. Allow the

 

projector to cool for at least 45 minutes.

2

3

Remove a screw with a screwdriver to remove Lamp Cover.

Remove 3 screws with a screwdriver and pull out Lamp Assembly by grasping Handle.

4

Replace Lamp Assembly with a new one and tighten 3 screws

LAMP

HANDLE

 

back. Make sure that Lamp Assembly is set properly. Replace

 

Lamp Cover and tighten a screw.

ASSEMBLY

 

5

6

Connect AC Power Cord to the projector and turn it on.

Reset Lamp Replace Counter (refer to the section “Lamp Replace Counter” below).

NOTE : Do not reset Lamp Replace Counter when Projection

Lamp is not replaced.

ORDER REPLACEMENT LAMP

Replacement Lamp can be ordered through your dealer. When ordering Projection Lamp, give the following information to the dealer.

● Model No. of your projector : LC-XNB3 / LC-XNB3W

Replacement Lamp Type No. : POA-LMP35

(Service Parts No. 610 293 2751)

LAMP REPLACE COUNTER

Be sure to reset Lamp Replace Counter when Lamp Assembly is replaced. When Lamp Replace Counter is reset, LAMP REPLACE Indicator stops lighting.

1

Turn projector on, press MENU button and ON-SCREEN MENU will appear. Press POINT LEFT/RIGHT button(s) to

 

move a red frame pointer to SETTING Menu icon (refer to page 35, 36).

2

Press POINT DOWN button to move a red frame pointer to “Lamp counter reset” and then press SELECT button. The

 

message "Lamp replace counter reset?" is displayed. Move the pointer to [Yes] and then press SELECT button.

3

Another confirmation dialog box appears and select [Yes] to reset Lamp Replace Counter.

Do not reset Lamp Replace Counter except after Projection Lamp is replaced.

39

Page 39
Image 39
Eiki LC-XNB3W owner manual Appendix Lamp Replacement, Lamp Replace Counter

LC-XNB3W, LC-XNB3 specifications

The Eiki LC-XNB3 is a powerful and versatile multimedia projector designed for professional presentations, educational institutions, and corporate environments. This projector combines advanced technology and practicality to deliver an exceptional viewing experience. With its compact design and lightweight structure, the LC-XNB3 is easy to transport and set up, making it a valuable asset in any meeting room or classroom.

One of the standout features of the Eiki LC-XNB3 is its impressive brightness rating of 3800 lumens. This high lumen output ensures that even in well-lit environments, presentations remain vibrant and clear. The projector's XGA resolution of 1024 x 768 pixels provides sharp and detailed images, making it suitable for displaying intricate graphics, spreadsheets, and video content with precision.

The LC-XNB3 employs a unique 3LCD technology, which enhances color brightness and improves overall image quality. This technology allows for a wider color gamut, resulting in vivid and lifelike images that captivate audiences. In addition, the projector boasts a high contrast ratio, providing deeper blacks and brighter whites to create more dynamic visuals.

Another notable characteristic of the Eiki LC-XNB3 is its connectivity options. It offers multiple input ports, including HDMI, VGA, and USB, allowing users to connect a variety of devices such as laptops, tablets, and smartphones. This flexibility ensures compatibility with various media sources and simplifies the process of sharing content during presentations.

The LC-XNB3 also features built-in speakers, providing clear audio that complements visual content without the need for additional external speakers. Additionally, the projector offers a range of presentation modes to optimize performance based on the environment and type of content being displayed.

For maintenance and longevity, the Eiki LC-XNB3 is equipped with a long-lasting lamp that can provide up to 6000 hours of use in eco mode. This durability minimizes the frequency of lamp replacements, reducing overall operating costs.

In summary, the Eiki LC-XNB3 is a highly capable multimedia projector that excels in delivering high-quality images and sound for various applications. Its robust features, impressive brightness, and versatile connectivity options make it an ideal choice for anyone looking to enhance their presentation capabilities.