El Paso Chile Company OM163, DMS 3120-120 manual Muting Priority Settings, Muting Switch, Shield

Models: DMS 3080-80 DMS 3120-120 OM163 DMS 3040-40

1 32
Download 32 pages 2.52 Kb
Page 11
Image 11

®

PROFESSIONAL AUDIO & SOUND

DIGITAL MUSIC AMPLIFIERS DIGITAL MUSIC SERIES

TM

INSTALLATION AND WIRING

INPUT 1 - USING A DESK BASE MICROPHONE

USING A PUSH-TO-TALK DESK BASE MICROPHONE Microphone paging and precedence over AUX 1 or AUX 2 channels may be accomplished by using a Desk Base or a Gooseneck Microphone. Wire the Microphone output leads to the MIC input ter- minals as per Fig. 11A.

CAUTION: TO PREVENT POSSIBLE DAMAGE TO SPEAKERS

OR THE AMPLIFIER ALL INPUT CONNECTIONS MUST BE

MADE WITH THE AMPLIFIER POWER OFF.

WIRING

MUTING: The Amplifier is equipped with two independent Muting Circuits:

zDirect Muting by shorting the MUTE Terminals

zAutomatic Muting with VOX - Voice Activated Muting

For additional information on the Muting operation refer to the Muting Functions section of this Manual.

Push to Talk Key

b50side

Fig. 11 - Desk Base Microphone

Wire the Desk Base Microphone leads to the Microphone Input terminal strip as per diagram in Fig 11A. Check Microphone instructions and connect HOT LEAD (B) to Terminal HOT, COMMON LEAD (A) to Terminal COM and SHIELD LEAD to Terminal G. Connect Muting Switch to Terminals MUTE 1 or MUTE 2 and G as shown.

DO NOT GROUND THE MICROPHONE CABLE SHIELD TO THE CHASSIS OF THE AMPLIFIER

MUTING - PRIORITY SETTINGS

Direct Muting is provided by the Desk Base Muting Switch wired as per diagram in Fig. 11A. If Auto-Mute (VOX) is desired follow instruc- tions below. The Desk Base Muting Switch can be omitted.

MUTING INPUT 4/AUX 1 (MUSIC INPUT)

To mute Input 4/AUX 1 (Music Input) when Paging from MIC 1, set INPUT 4/AUX 1 MUTE 1 JUMPER to ON Position. Each time MIC 1 is activated the Program on Input 4/AUX 1 is automatically muted by the VOX.

DESK BASE/GOOSENECK MICROPHONE WITH MUTING SWITCH

VOX - MUTE JUMPERS SETTING

 

 

 

 

 

 

 

 

SW215

VOX 1 BUSS

 

 

 

 

 

 

 

 

 

 

 

 

V1

 

OFF

 

ACTIVATED

 

 

 

 

 

 

JUMPER

 

 

 

 

 

 

 

 

 

 

 

 

 

VOX SEND

 

 

 

X

 

 

 

 

V2

 

 

 

 

 

 

 

 

 

 

VOX 2 BUSS OFF

 

 

 

 

 

 

 

 

GROUND

MUTE2

MUTE1

 

 

 

 

 

 

VOLUME

 

 

 

 

 

 

 

 

MASTER

 

 

 

= JUMPER

 

 

 

REMOTE

MIC IN

AUDIO OUT

 

G

M2

M1

RVC RVC

Push to Talk Key

 

 

 

 

 

INPUT 1

 

 

 

 

 

 

 

 

 

 

 

SW220

 

 

 

 

 

M1

OFF

JUMPER

MUTE 1 BUSS OFF

 

 

 

INPUT 1 (MIC)

X

 

 

 

 

G COM HOT

 

 

 

 

 

MUTE RECEIVE

 

 

 

 

 

 

M2

X

 

 

 

 

 

 

 

 

MUTE 2 BUSS OFF

 

 

 

 

 

 

 

 

 

 

 

 

Connect Desk Base or Gooseneck

 

 

 

MUTING SWITCH

 

 

 

 

 

 

 

 

 

 

 

 

Microphone as per diagram below.

 

 

 

 

 

SHIELD

 

Connect Muting Switch to MUTE 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

or MUTE 2 and G Terminals.

 

 

 

 

 

 

 

A

If using the VOX system the

 

 

 

 

 

 

 

 

 

MIC

 

 

 

 

B

muting switch is unnecessary.

 

 

 

 

 

 

 

 

 

Lo Z

 

 

 

 

 

INPUT 1 - Default Jumper Settings The Diagram at Left shows the Default Settings for INPUT 1.

VOX 1 is SWITCHED ON

VOX 2 is SWITCHED OFF

MUTE 1 is SWITCHED OFF

MUTE 2 is SWITCHED OFF

When the INPUT 1 (MIC 1) is activated the VOX 1 BUSS is ON and it will MUTE any Input with the MUTE 1 Setting SWITCHED ON.

250ohm 1.5mV

BALANCED

 

 

INPUT 3

(MIC)

INPUT 2 (MIC)

 

 

 

 

 

 

G COM HOT

 

G COM

HOT

 

 

 

 

 

 

 

NOTE: To change the INPUT Default Settings refer to the appropriate section in this Manual

3120 Micbase 01

Fig. 11A - Input 1 and Muting Terminals

DMS3040/3080/3120

SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE

PAGE 11

Page 11
Image 11
El Paso Chile Company OM163, DMS 3120-120, DMS 3080-80, DMS 3040-40 manual Muting Priority Settings, Muting Switch, Shield