Routing Software 06-02 (OS3) Installation Guide
4S-9181-31X
2.1 Update Procedure 1
This is an update procedure for a GR2000 that is configured from one RM using two
MCs. It updates the backup and current MCs, both with an old version of software
stored in them. After the update for the current MC is complete, the GR2000
automatically restarts. Upon restart, communication is interrupted temporarily. Do
not pull out and insert an MC card while updating the software.
1. Log into a GR2000 with a user ID that the user has set (for example, RSHUDWRU).
2. Enter a admin command. The command prompt changes to DGPLQ:.
3. Execute a version command to check that the version in current use is one of
software versions from which the update is allowed as listed in Table 2-3.
4. Execute an information router command to check that individual capacities of free
space in MC0 and MC1of rm0 are equal to or larger than the capacity listed in
Table 2-3.
5. Execute a synchronize –s secondary command to check that the current MC is
identical to the backup MC in the configuration definition, the password file, and
the user account. If not identical, execute a synchronize –a secondary command to
make them identical to each other.
6. Transfer with FTP the files listed in Table 2-1 to a place under the /primaryMC/usr/
var/update directory in the GR2000 by the file name of 83'$7(WJ] (be sure to
transfer in the binary mode).
7. Execute ls –l /primaryMC/usr/var/update to check that the size of transferred files is
the same as the size of files in the CD-ROM individually.
8. Enter cd /primaryMC/usr/var/update to change to the relevant directory.
9. Execute ppupdate UPDATE.tgz secondary act to update the backup MC.
10.Execute ppupdate UPDATE.tgz primary act to update the current MC.
11.After completion of the update, the message 5HERRWDFWLYH50DIWHUVHFRQGV
is displayed. The GR2000 automatically restarts 30 seconds later.
12.The update of the MCs is now complete. After the GR2000 restarts, log in again,
and execute a version command to check that the GR2000 is operating with the
new version.